A side-by-side comparison of sampling methods for settled, indoor allergens.

نویسندگان

  • M Mansour
  • B P Lanphear
  • R Hornung
  • J Khoury
  • D I Bernstein
  • W Menrath
  • J Decolongon
چکیده

Exposure to indoor allergens is associated with asthma, but there is no standardized sampling method for measuring allergens. We compared the association of measured allergen exposure and serum-specific IgE levels and the precision of three sampling methods (Cyclone, Mighty Mite, and Readivac II) to identify a standardized sampling method for indoor allergens. A random sample of 72 children, 5 to 17 years old, with doctor-diagnosed asthma who lived in the same residence >or=2 years were enrolled. Composite, side by side floor samples were obtained with all three methods. Dust allergen concentrations and serum-specific IgE levels were measured for Der f I, Fel d I, and Bla g I. Mean allergen concentration did not differ significantly by sampling method. Cat allergen was significantly correlated with serum-specific IgE for Cyclone (P=0.003) and Mighty Mite (P=0.008), but only marginally for Readivac II (P=0.07). Dust mite allergen was significantly correlated with serum-specific IgE for Readivac II (P=0.02) and Cyclone (P=0.038), but not for Mighty Mite (P=0.12). Cockroach allergen was not correlated with serum-specific IgE for any sampling method. In multiple linear regression, cat allergen was associated with serum-specific IgE for Cyclone (P=0.007) and Mighty Mite (P=0.02), but not for Readivac II (P=0.06). In contrast, dust mite allergen was marginally associated with serum-specific IgE for Readivac II (P=0.07), but not for Mighty Mite (P=0.64) or Cyclone (P=0.27). The Cyclone and Mighty Mite were more precise than Readivac II for cat allergen, but there was no difference for dust mite allergen (P>0.05). No single method is superior for measurement of indoor allergens. In general, cat allergen collected with the Cyclone was a better predictor of serum-specific IgE levels to Fel d I, whereas dust mite allergen collected with the Readivac II was a better predictor of serum-specific IgE levels to Der f I.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Particulate Matter Investigation in Indoor Environment

Particulate matter is one of the most important indoor air pollutants involved in a number of adverse health effects, such as premature deaths and increased mortality of infants and other parts of sensitive population. This paper focuses on investigation of metal substances of suspended as well as settled particulate matter in indoor environment. The monitoring of particulate matter concentrati...

متن کامل

designing and implementing a 3D indoor navigation web application

​During the recent years, the need arises for indoor navigation systems for guidance of a client in natural hazards and fire, due to the fact that human settlements have been complicating. This research paper aims to design and implement a visual indoor navigation web application. The designed system processes CityGML data model automatically and then, extracts semantic, topologic and geometric...

متن کامل

Assessment of fungal contamination in moldy homes: comparison of different methods.

In an effort to better understand the relationship between different fungal sampling methods in the indoor environment, four methods were used to quantify mold contamination in 13 homes with visible mold. Swab, fungal spore source strength tester (FSSST), and air samples (total of 52 samples) were analyzed using both the microscopic (total spore count) and culture-based (CFU count) enumeration ...

متن کامل

Feasibility of Using Subject-Collected Dust Samples in Epidemiologic and Clinical Studies of Indoor Allergens

Studies of indoor allergen exposures are often limited by the cost and logistics of sending technicians to homes to collect dust. In this study we evaluated the feasibility of having subjects collect their own dust samples. The objectives were to compare allergen concentrations between subject- and technician-collected samples and to examine the sample return rate. Using a dust collection devic...

متن کامل

طراحی، اجرا و بررسی عملکرد مولد میست کروم شش ظرفیتی

Background and aim: The chromium mist generator is an essential tool for research and for making evidence-based recommendations in evaluating air pollution and its control systems. The purpose of this study was to design and construct a homogeneous chromium mist generator and to look at the effects of factors such as sampling height and distance between samplers in side-by-side sampling on the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental research

دوره 87 1  شماره 

صفحات  -

تاریخ انتشار 2001