The importance of assessing corneal biomechanical properties in glaucoma patients care - a review.
نویسندگان
چکیده
Purpose: to familiarize the public with the role of corneal biomechanics in glaucoma patient management. Methods: Ocular Response Analyzer (ORA) is the only device that measures in vivo corneal biomechanics. Recent studies regarding "corneal biomechanics and glaucoma" were reviewed and the obtained data were compared in order to present a better understanding of the corneal biomechanical properties involvement in glaucoma care. Results: According to the studies reviewed, in primary open angle glaucoma (POAG) the mean corneal hysteresis (CH) and the corneal resistance factor (CRF) were approximately 2 mmHg lower than in normal eyes. In ocular hypertension (OH), the mean CH was about 1mmHg higher than in POAG patients and 1mmHg lower than in the control group, while the mean CRF was about 2mmHg higher than in POAG and 1mmHg higher than in the control group. Regarding the normal tension glaucoma (NTG), there were studies that showed that the mean CH and CRF were approximately 1mmHg lower than in POAG and studies that showed similar values between the POAG and NTG groups. The mean CH did not differ much between POAG and angle closure glaucoma (ACG), being lower than in normal individuals, while CRF appeared to be higher in the ACG than in normal individuals. Concerning congenital glaucoma (CG), both CH and CRF were about 2mmHg lower than in normal eyes. Conclusions: Corneal biomechanics influenced the IOP measurement and have been proven to be of a great significance in glaucoma patients regardless of the central corneal thickness (CCT). Lower values of CH and CRF could suggest an alteration in the corneal response associated to glaucoma.
منابع مشابه
Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...
متن کاملCorneal properties and glaucoma: a review of the literature and meta-analysis.
PURPOSE Studies have suggested that corneal biomechanical properties influence intraocular pressure (IOP) measurements, namely central corneal thickness (CCT) and corneal hysteresis (CH). The present study aimed to investigate the associations of CH and CCT with glaucoma development. METHODS We performed a review of the literature and meta-analysis of observational studies (2006-2016) that in...
متن کاملOcular Response Analyzer
Until recently, corneal biomechanical properties could not be measured in vivo. The ocular response analyzer is a new, noninvasive device that analyses corneal biomechanical properties simply and rapidly. The ORA allows cornea compensated IOP measurements and can estimate corneal hysteresis (CH) and corneal resistance factor (CRF). It is designed to improve the accuracy of IOP measurement by us...
متن کاملAnterior-segment morphology and corneal biomechanical characteristics in pigmentary glaucoma
PURPOSE The aim of the study reported here was to evaluate characteristics of the anterior-segment via anterior-segment optical coherence tomography (AS-OCT) and corneal biomechanical properties using an ocular response analyzer and their changes by peripheral laser iridotomy (PI) in patients with pigmentary glaucoma (PG). MATERIALS AND METHODS Seventeen eyes with PG were included consecutive...
متن کاملImpact of Myopia on Corneal Biomechanics in Glaucoma and Nonglaucoma Patients
Purpose We evaluated the impact of myopia on corneal biomechanical properties in primary open-angle glaucoma (POAG) and nonglaucoma patients, and the effect of modification of glaucoma on myopic eyes. Methods This cross-sectional study included 66 POAG eyes (33 myopia, 33 nonmyopia) and 66 normal eyes (33 myopia, 33 nonmyopia). Seven corneal biomechanical parameters were measured by ultra-hig...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Romanian journal of ophthalmology
دوره 60 4 شماره
صفحات -
تاریخ انتشار 2016