Background: Hip fractures are a leading cause of death and disability among elderly. Approximately half of these injuries are intertrochanteric fractures and the incidence is continuously increasing. It is estimated that the incidence of intertrochanteric fractures will be doubled by the year 2040. Different types of implants were tried at different times for internal fixation of these fractures, of which dynamic hip screw has remained the most popular one. But with the advent of some newer implants, the efficacy of dynamic hip screw is being questioned. Aims: To determine the frequency of failure after dynamic hip screw fixation of intertrochanteric fracture and to identify causes (instability, increased tip apex distance and high angle side plate) leading to failure after dynamic hip screw fixation of intertrochanteric fracture. Design: Descriptive case series. Setting: The study was conducted in Orthopaedic ward of Ghurki Trust Teaching Hospital/Lahore Medical & Dental College, Lahore. Duration of study: Six months (15 th November, 2008 to 15 th May, 2009) Methods: Forty five cases of intertrochanteric fractures were included and operated for internal fixation with dynamic his screw under fluoroscopic guidance. Pre, per and post-operative findings during hospital stay and follow-up period were recorded. Results: There were 32 males and 13 females with male to female ratio were 2.5:1. The mean±SD between the ages was 71.91±10.40 years. Thirty one patients were admitted through emergency and 14 patients through outdoor patient department. The size of lag screw in 12 patients of 85 mm screw and 33 patients of 900 mm screw were used. Three types of interlocking nail of 45 mm, 50 mm and 55 mm sizes were used. The failure rate was found in 22 patients of grade III, 15 patients of grave IV and 8 patients of grade V of dynamic hip screw fixation through Hammer et al radiological assessment of callus formation. At Sirkoski and Barrington pain scale, the failure rate was found in 28 patients of grade III and 17 patients of grade IV. Conclusion: The use of this implant is associated with satisfactory result and acceptable complication rate, given the poor physical status of many of these elderly patients before the injury.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques

Background: At present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. The aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (DHS) and bipolar hemiarthroplasty in elderly patients with background medical conditions. Methods: In this randomi...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...

متن کامل

Comparing Therapeutic Outcomes of Dynamic Hip Screw and Multiple Cannulated Screws as Internal Fixation in Femoral Neck Fractures

Background and purpose: Femoral neck fracture is associated with a high rate of side effects, especially in young people, who are usually affected by severe energy shocks. Results after injury depend on some factors, including displacement, fragility, bleeding rate, proper placement, and stable and strong fixation. The aim of this study was to compare dynamic hip screw (DHS) or multiple cannula...

متن کامل

A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation.

OBJECTIVES To establish a laboratory model of implant cutout, which can evaluate the effect of implant design on cutout resistance in a clinically realistic "worst case" scenario. SETTING Orthopaedic biomechanics laboratory. DESIGN Implant cutout was simulated in an unstable pertrochanteric fracture model, which accounted for dynamic loading, osteoporotic bone, and a defined implant offset....

متن کامل

شکستگی ساب کاپیتال گردن فمور بعد از جوش خوردگی شکستگی اینترتروکانتریک

Abstract We report a 71 year-old patient with intertrochanteric fracture who had been managed with DHS and her healed fracture complicated by a subcapital femoral neck fracture. A subcapital femoral neck fracture complicating a healed intertrochanteric fracture is rare but catastrophic event. Such cases are managed in a hetereogenous manner, i.e. there exists a mixture of cases tr...