Disparate Body Composition Outcomes for Underwater Weighing, Dual-Energy X-Ray Absorptiometry, and Two Bioelectrical Impedance Devices in Overweight Young Adults

نویسندگان

  • Michelle Alencar
  • Kelly E. Johnson
  • Nathan Cole
  • Ann L. Gibson
چکیده

Introduction: As the prevalence of obesity rises, so does the need for reliable Body Composition (BC) methods. Many methods of BC analysis exist, however validity between methods has been questioned. Uncertainty exists within the scientific literature about which laboratory method and field measurement is applicable for the overweight population to estimate Percent Body Fat (% BF). There is scarce research comparing Hydrostatic Weighing (HW) and Dual Energy X-Ray Absorptiometry (DXA) with field methods in overweight individuals. The purpose of this study was to compare HW and DXA with Multi-Frequency (MF-BIA) and a Single-Frequency (SFBIA) Bioelectrical Impedance (BIA) device. Methods: Twenty-five overweight and obese adults (BMI 30.1 ± 4.1 kg/ m2, 13 males, 12 females, ages 24.6 ± 4.7y) were randomly assessed by vertical SF-BIA, and supine MF-BIA against DXA and lastly HW. All participants followed standardized pre-testing guidelines for BC assessment. Agreement was assessed using a 2 (group) x 4 (method) RMANOVA and post-hoc t-tests were applied as appropriate. All methods of body composition were used and compared to DXA and HW. Results: Significant main effects between BC methods were observed F (1, 23) = 63.8, p < 0.001). Where % BF values were higher using the DXA (34.2 ± 10.6 %) vs. HW (28.2 ± 9.3 %) (p < 0.001). Additionally, % BF values were higher using the MF-BIA (30.9 ± 58.8 %) compared to the SF-BIA (26.2 ± 8.0%) (p < 0.001). %BF values were significantly correlated between SF-BIA and HW (p < 0.05, r = 0.902) as well as between MF-BIA and DXA (p < 0.05, r = 0.709). Conclusions: Differences in %BF were evident when comparing the vertical SF-BIA and supine MF-BIA with HW and DXA. The field method SF-BIA was found to correlate with the laboratory method HW. Whereas the field method MF-BIA was found to correlate with DXA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of bioelectrical impedance consumer devices for measurement of body composition in comparison to whole body magnetic resonance imaging and dual X-ray absorptiometry.

OBJECTIVE To compare body composition determined by bioelectrical impedance (BIA) consumer devices against criterion estimates determined by whole body magnetic resonance imaging (MRI) and dual energy X-ray absorptiometry (DXA) in healthy normal weight, overweight and obese adults. METHODS In 106 adults (54 females, 52 males, age 54.2 +/- 16.1 years, BMI 25.8 +/- 4.4 kg/m(2)) fat mass (FM), s...

متن کامل

Comparisons of a Multi-Frequency Bioelectrical Impedance Analysis to the Dual-Energy X-Ray Absorptiometry Scan in Healthy Young Adults Depending on their Physical Activity Level

This study aimed at comparing BIA and DXA results in assessing body composition in young adults depending on their physical activity level. Eighty healthy 19-30 years old subjects were enrolled and their body composition (Fat Mass and Fat-Free Mass) was assessed by dual-energy X-ray absorptiometry (DXA) and by a newly developed Bioelectrical Impedance Analyzer (BIA - Tanita MC780). A seven-day ...

متن کامل

Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans.

The present study assessed the relative contribution of each body segment to whole body fat-free mass (FFM) and impedance and explored the use of segmental bioelectrical impedance analysis to estimate segmental tissue composition. Multiple frequencies of whole body and segmental impedances were measured in 51 normal and overweight women. Segmental tissue composition was independently assessed b...

متن کامل

Validity of segmental multiple-frequency bioelectrical impedance analysis to estimate body composition of adults across a range of body mass indexes.

OBJECTIVE We compared body composition estimates using an eight-electrode, segmental, multiple-frequency bioelectrical impedance analysis (segmental MF-BIA) and dual x-ray absorptiometry (DXA) in a group of healthy adults with a range of body mass indexes (BMIs). METHODS Percentage of body fat (%BF), fat-free mass, and fat mass assessed by DXA and segmental MF-BIA in 132 healthy adults were c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017