Biomechanical Characterization of Subclinical Keratoconus Without Topographic or Tomographic Abnormalities.
نویسندگان
چکیده
PURPOSE To present a case series of patients with subclinical keratoconus with normal topometric (anterior curvature) and tomographic findings in one eye who showed abnormalities detected by Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) in vivo biomechanical assessment. METHODS All patients had a complete ophthalmic examination, including the Corvis ST biomechanical measurements, optical tomography, and pachymetry with Pentacam (Oculus Optikgeräte GmbH), and Placido-based topography with either the Nidek (OPD III Nidek, Gamagori, Japan) or CSO platform (Costruzione Strumenti Oftalmici, Florence, Italy). Inclusion criteria were a clinical diagnosis of ectasia in one eye and normal topometric and tomographic findings in the fellow eye (subclinical keratoconus), including a Belin/Ambrósio Enhanced Ectasia total deviation index from the Pentacam with less than 1.6 standard deviations from normative values and a Corvis Biomechanical Index score of greater than 0.5 in both eyes. RESULTS Tomographic and topographic analysis was normal in one eye and abnormal in the fellow eye in 12 patients. The biomechanical results with the Corvis Biomechanical Index were shown to be abnormal in both eyes of all patients and aided the diagnosis. CONCLUSIONS Biomechanical analysis showed abnormalities, whereas tomography and topography were normal. Basing on these findings, the authors suggest the use of biomechanics as an additional diagnostic tool. [J Refract Surg. 2017;33(6):399-407.].
منابع مشابه
Complementary Keratoconus Indices Based on Topographical Interpretation of Biomechanical Waveform Parameters: A Supplement to Established Keratoconus Indices
Purpose. To build new models with the Ocular Response Analyzer (ORA) waveform parameters to create new indices analogous to established topographic keratoconus indices. Method. Biomechanical, tomographic, and topographic measurements of 505 eyes from the Homburger Keratoconus Centre were included. Thirty-seven waveform parameters (WF) were derived from the biomechanical measurement with the ORA...
متن کاملA Contralateral Eye Study Comparing Corneal Biomechanics in Subjects with Bilateral Keratoconus with Unilateral Vogt’s Striae
The aim of this study was to analyze and compare corneal biomechanics in patients with bilateral keratoconus (KCN) with unilateral Vogt's striae. In this prospective contralateral study, visual acuity, refraction, and corneal biomechanical parameters were evaluated in patients with bilateral KCN with unilateral Vogt's striae using the Ocular Response Analyzer (ORA) (Reichert Inc., Buffalo, NY) ...
متن کاملRisk Factors for Failure of Keratoplasty in Keratoconus: Penetrating vs. Deep Anterior Lamellar Keratoplasty
Purpose: To determine the etiologic factors on rejection and failure rates and ocular surface changes after corneal transplantation by either DALK or PKP, in cases of keratoconus (KCN). Methods: In this cross-sectional study, considering the existing data, patients with keratoconus referring to Labbafinejad Medical Center from 2006 to 2016, who underwent corneal transplantation, were enrolled a...
متن کاملConsideration of corneal biomechanics in the diagnosis and management of keratoconus: is it important?
Keratoconus is a bilateral, non-inflammatory, degenerative corneal disease. The occurrence and development of keratoconus is associated with corneal thinning and conical protrusion, which causes irregular astigmatism. With the disruption of the collagen organization, the cornea loses its shape and function resulting in progressive visual degradation. Currently, corneal topography is the most im...
متن کاملMultivariate Analysis of the Ocular Response Analyzer's Corneal Deformation Response Curve for Early Keratoconus Detection
Purpose. To thoroughly analyze corneal deformation responses curves obtained by Ocular Response Analyzer (ORA) testing in order to improve subclinical keratoconus detection. Methods. Observational case series of 87 control and 73 subclinical keratoconus eyes. Examination included corneal topography, tomography, and biomechanical testing with ORA. Factor analysis, logistic regression, and receiv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 33 6 شماره
صفحات -
تاریخ انتشار 2017