Photoacoustic spectroscopy of surface adsorbed molecules using a nanostructured coupled resonator array.

نویسندگان

  • Dongkyu Lee
  • Seonghwan Kim
  • C W Van Neste
  • Moonchan Lee
  • Sangmin Jeon
  • Thomas Thundat
چکیده

A rapid method of obtaining photoacoustic spectroscopic signals for trace amounts of surface adsorbed molecules using a nanostructured coupled resonator array is described. Explosive molecules adsorbed on a nanoporous anodic aluminum oxide cantilever, which has hexagonally ordered nanowells with diameters and well-to-well distances of 35 nm and 100 nm, respectively, are excited using pulsed infrared (IR) light with a frequency matching the common mode resonance frequency of the coupled resonator. The common mode resonance amplitudes of the coupled resonator as a function of illuminating IR wavelength present a photoacoustic IR absorption spectrum representing the chemical signatures of the adsorbed explosive molecules. In addition, the mass of the adsorbed molecules as an orthogonal signal for quantitative analysis is determined by measuring the variation of the localized, individual mode resonance frequency of a cantilever on the array. The limit of detection of the ternary mixture of explosive molecules (1:1:1 of trinitrotoluene (TNT), cyclotrimethylene trinitramine (RDX) and pentaerythritol tetranitrate (PETN)) is estimated to be ~ 100 ng cm(-2). These multi-modal signals enable us to perform quantitative and rapid chemical sensing and analysis in ambient conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhanced photoacoustic detection using photonic crystal substrate

This paper demonstrates the enhanced photoacoustic sensing of surface-bound light absorbing molecules and metal nanoparticles using a one-dimensional photonic crystal (PC) substrate. The PC structure functions as an optical resonator at the wavelength where the analyte absorption is strong. The optical resonance of the PC sensor provides an intensified evanescent field with respect to the excit...

متن کامل

B-Mode Photoacoustic Imaging using Linear Array: Numerical Study for Forward-Backward Minimum Variance Beamformer Combined with Delay-Multiply-and-Sum

Photoacoustic imaging (PAI) is a promising medical imaging modality which provides the resolution of Ultrasound (US) and the contrast of Optical imaging modalities. One of the most important challenges in PAI is image formation, especially in the case that a linear-array US transducer is used for data acquisition. This is due to the fact that in the linear-array scenario, there is only 60 degre...

متن کامل

Analytical Study of Optical Bi-Stability of a Single-Bus Resonator Based on InGaAs Micro-Ring Array

In this paper, for the first time to our knowledge, we investigate the optical bi-stability in a compact parallel array of micro- ring resonators with 5μm radius, induced by optical nonlinearity. Due to the nature of perfect light confinement, resonance and accumulation process in a ring resonator, optical nonlinear effects, even at small optical power of a few milliwatts in this structure are ...

متن کامل

All-Semiconductor Plasmonic Resonator for Surface-Enhanced Infrared Absorption Spectroscopy

Infrared absorption spectroscopy remains a challenge due to the weak light-matter interaction between micron-wavelengthed infrared light and nano-sized molecules. A highly doped semiconductor supports intrinsic plasmon modes at infrared frequencies, and is compatible with the current epitaxial growth processing, which makes it promising for various applications. Here, we propose an all-semicond...

متن کامل

Tranexamic Acid as Novel Corrosion Inhibitor for X60 Steel in Oil Well Acidizing Fluids: Surface Morphology, Gravimetric and Electrochemical Studies

The corrosion inhibition of API 5L X60 pipeline steel in oil well acidizing fluid stimulated with 1.0 M HCl by Tranexamic Acid (TXA) was investigated using potentiodynamic polarization (PDP), electrochemical impedance spectroscopy (EIS) and the conventional gravimetric or weight loss (WL) techniques at temperatures ranging from 303 to 323 K. Surface morphological analysis was carried out us...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nanotechnology

دوره 25 3  شماره 

صفحات  -

تاریخ انتشار 2014