Helical tomotherapy radiation leakage and shielding considerations.
نویسندگان
چکیده
Leakage radiation and room shielding considerations increase significantly for intensity-modulated radiation therapy (IMRT) treatments due to the increased beam-on time to deliver modulated fields. Tomotherapy, with its slice by slice approach to IMRT, further exacerbates this increase. Accordingly, additional shielding is used in tomotherapy machines to reduce unwanted radiation. The competing effects of the high modulation and the enhanced shielding were studied. The overall room leakage radiation levels are presented for the continuous gantry rotations, which are always used during treatments. The measured leakage at 4 m from the isocenter is less than 3 x 10(-4) relative to calibration output. Primary radiation exposure levels were investigated as well. The effect of forward-directed leakage through the beam-collimation system was studied, as this is the leakage dose the patient would receive in the course of a treatment. A 12-min treatment was calculated to produce only 1% patient leakage dose to the periphery region. Longer treatment times might yield less patient dose if the field width selected is correspondingly narrower. A method for estimating the worst-case leakage dose a patient would receive is presented.
منابع مشابه
Out‐of‐field dosimetry measurements for a helical tomotherapy system†
Helical tomotherapy is a rotational delivery technique that uses intensity-modulated fan beams to deliver highly conformal intensity-modulated radiation therapy (IMRT). The beam-on time needed to deliver a given prescribed dose can be up to 15 times longer than that needed using conventional treatment delivery. As such, there is concern that this delivery technique has the potential to increase...
متن کاملRadiation characteristics of helical tomotherapy.
Helical tomotherapy is a dedicated intensity modulated radiation therapy (IMRT) system with on-board imaging capability (MVCT) and therefore differs from conventional treatment units. Different design goals resulted in some distinctive radiation field characteristics. The most significant differences in the design are the lack of flattening filter, increased shielding of the collimators, treatm...
متن کاملQuality assurance of the multileaf collimator with helical tomotherapy: design and implementation.
Quality assurance (QA) of the multileaf collimator (MLC) is a critical step for the delivery of intensity modulated radiation therapy treatment plan. While QA procedures for motor-driven MLC have been published extensively, those for binary MLCs such as the one used for helical tomotherapy have not been presented in the literature, as this is still a fairly new technology. In this study, seven ...
متن کاملThe evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
متن کاملAnalysis of peripheral doses for base of tongue treatment by linear accelerator and helical TomoTherapy IMRT
The purpose of this study was to compare the peripheral doses to various organs from a typical head and neck intensity-modulated radiation therapy (IMRT) treatment delivered by linear accelerator (linac) and helical TomoTherapy. Multiple human CT data sets were used to segment critical structures and organs at risk, fused and adjusted to an anthropomorphic phantom. Eighteen contours were design...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 32 3 شماره
صفحات -
تاریخ انتشار 2005