A biomechanical comparison of kyphoplasty using a balloon bone tamp versus an expandable polymer bone tamp in a deer spine model.
نویسندگان
چکیده
We performed a biomechanical study to compare the augmentation of isolated fractured vertebral bodies using two different bone tamps. Compression fractures were created in 21 vertebral bodies harvested from red deer after determining their initial strength and stiffness, which was then assessed after standardised bipedicular vertebral augmentation using a balloon or an expandable polymer bone tamp. The median strength and stiffness of the balloon bone tamp group was 6.71 kN (sd 2.71) and 1.885 kN/mm (sd 0.340), respectively, versus 7.36 kN (sd 3.43) and 1.882 kN/mm (sd 0.868) in the polymer bone tamp group. The strength and stiffness tended to be greater in the polymer bone tamp group than in the balloon bone tamp group, but this difference was not statistically significant (strength p>0.8, and stiffness p=0.4).
منابع مشابه
An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture.
STUDY DESIGN Ex vivo biomechanical study using osteoporotic cadaveric vertebral bodies. OBJECTIVES To determine if the inflatable bone tamp (tamp) restores height to compressed vertebral bodies and to compare the biomechanical properties of isolated, fractured osteoporotic vertebral bodies treated by kyphoplasty (tamp) or vertebroplasty. SUMMARY OF BACKGROUND DATA Previous biomechanical stu...
متن کاملAn ex vivo evaluation of an inflatable bone tamp used to reduce fractures within vertebral bodies under load.
STUDY DESIGN Ex vivo biomechanical study using osteoporotic cadaveric vertebral bodies. OBJECTIVE To determine if fracture reduction could be achieved by the inflatable bone tamp (tamp) in vertebral bodies under simulated physiologic loads. SUMMARY OF BACKGROUND DATA Previous ex vivo biomechanical studies showed that kyphoplasty restored vertebral body height with vertebral body endplates u...
متن کاملRadiofrequency-targeted vertebral augmentation versus traditional balloon kyphoplasty: radiographic and morphologic outcomes of an ex vivo biomechanical pilot study [Erratum]
PURPOSE Traditional balloon kyphoplasty (BK) is a common treatment for symptomatic vertebral compression fractures. The purpose of this study was to compare a novel vertebral augmentation technique, radiofrequency-targeted vertebral augmentation (RF-TVA), to BK for restoration of vertebral height, cavity creation, and polymethylmethacrylate (PMMA) delivery and interdigitation into the surroundi...
متن کاملInitial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures.
STUDY DESIGN An Institutional Review Board-approved Phase I efficacy study of inflatable bone tamp usage in the treatment of symptomatic osteoporotic compression fractures. OBJECTIVES To evaluate the safety and efficacy of inflatable bone tamp reduction and cement augmentation, "kyphoplasty," in the treatment of painful osteoporotic vertebral compression fractures. SUMMARY OF BACKGROUND DAT...
متن کاملAn ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty.
BACKGROUND AND PURPOSE Previous ex vivo biomechanical studies have shown that kyphoplasty with polymethylmethacrylate cement increases vertebral body (VB) strength and restores VB stiffness and height after compression fracture. The purpose of the current study was to determine if a hydroxyapatite cement used as a void filler during kyphoplasty provides mechanical stabilization similar to that ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 89 2 شماره
صفحات -
تاریخ انتشار 2007