Comparison between a new platelet count drop method PL-11, light transmission aggregometry, VerifyNow aspirin system and thromboelastography for monitoring short-term aspirin effects in healthy individuals.

نویسندگان

  • Jie Guan
  • Yulong Cong
  • Junwei Ren
  • Yuan Zhu
  • Li Li
  • Xinli Deng
  • Jie Bai
چکیده

Platelet function has been described by many laboratory assays, and PL-11 is a new point-of-care platelet function analyzer based on platelet count drop method, which counts platelet before and after the addition of agonists in the citrated whole blood samples. The present study sought to compare PL-11 with other three major more established assays, light transmission aggregometry (LTA), VerifyNow™ aspirin system and thromboelastography (TEG), for monitoring the short-term aspirin responses in healthy individuals. Ten healthy young men took 100 mg/d aspirin for 3-day treatment. Platelet function was measured via PL-11, LTA, VerifyNow and TEG, respectively. The blood samples were collected at baseline, 2 hour, 1 day during the aspirin treatment and 1 day, 5 ± 1 days, 8 ± 1 days after the aspirin withdrawal. Moreover, 90 additional healthy subjects were recruited to establish a reference range for PL-11. Platelet function of healthy subjects decreased significantly 2 hours after 100 mg/d aspirin intake and began to recover during 4-6 days after the aspirin withdrawal. Correlations between methods were PL-11 vs. LTA (r = 0.614, p < 0.01); PL-11 vs. VerifyNow (r = 0.829, p < 0.01); PL-11 vs. TEG (r = 0.697, p < 0.001). There was no significant bias between PL-11 and LTA at baseline (bias = 1.94%, p = 0.804) using Bland-Altman analysis, while the data of PL-11 were significantly higher than LTA (bias = 24.02%, p < 0.001) during the aspirin therapy. The reference range for PL-11 in healthy young individuals was from 66.8 to 90.5% (95%CI). When aspirin low-responsiveness was defined as LTA > 20%, the cut-off values for each method were, respectively: PL-11 > 50%, VerifyNow > 533 ARU, TEG > 60.2%. The results of different platelet function assays were uninterchangeable for monitoring aspirin response and correlations among them were also varied. Correlations among PL-11 and other three major assays suggested the ability of PL-11 to assess the treatment effects of aspirin. But a large cohort study is needed to confirm the cut-off value of aspirin response detected by PL-11.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aspirin responsiveness in healthy volunteers measured with multiple assay platforms.

BACKGROUND We evaluated the sensitivity, precision, and concordance of 4 assays designed to detect aspirin responsiveness or resistance. METHODS Twenty-nine healthy laboratory volunteers took 80 mg aspirin for 7 days, and a subset of volunteers took 325 mg aspirin for an additional 7 days. We measured platelet function by light transmission aggregometry with arachidonic acid, PFA-100, and Ver...

متن کامل

Comparison of current platelet functional tests for the assessment of aspirin and clopidogrel response. A review of the literature.

The two most widely used antiplatelet drugs in the world are aspirin and clopidogrel. However, some patients on aspirin and/or clopidogrel therapy do not respond appropriately to either aspirin or clopidogrel. This phenomenon is usually called "aspirin/clopidogrel resistance". Several platelet function tests have been used in various studies for the assessment of aspirin and clopidogrel resista...

متن کامل

Comparison of current platelet functional tests for the assessment of aspirin and clopidogrel response

The two most widely used antiplatelet drugs in the world are aspirin and clopidogrel. However, some patients on aspirin and/or clopidogrel therapy do not respond appropriately to either aspirin or clopidogrel. This phenomenon is usually called “aspirin/clopidogrel resistance”. Several platelet function tests have been used in various studies for the assessment of aspirin and clopidogrel resista...

متن کامل

Comparison of antiplatelet activity of garlic tablets with cardio-protective dose of aspirin in healthy volunteers: a randomized clinical trial

Objective: Some of the adverse effects of aspirin including peptic ulcers, gastrointestinal bleeding and aspirin resistance compelled researchers to find a suitable alternative with fewer adverse effects. In this clinical trial, we aimed to find the effective antiplatelet dose of garlic. Materials and Methods: This randomized controlled clinical trial (RCT) was conducted on 62 healthy volunteer...

متن کامل

A comparison of platelet function tests and thromboxane metabolites to evaluate aspirin response in healthy individuals and patients with coronary artery disease.

Individualised antiplatelet therapy and platelet function testing have attracted considerable clinical interest, but several aspects of test performance have not been thoroughly evaluated. We investigated repeatability and concordance of light transmission aggregometry (LTA) induced with arachidonic acid (AA) 1.0 mM, PFA-100 induced with collagen/epinephrine, multiple electrode aggregometry (ME...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Platelets

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 2015