Recycling of Renewable Resources in Extra corporeal Circulation Technology
نویسنده
چکیده
This project evaluated the cost effectiveness and feasibility for recycling of renewable resources and disposing of non-recyclable materials generated in the perfusion department of an open heart surgery program. Forty-one adult and pediatric open heart cases were randomly assigned to participate as the control or the recycling group. The control group had no separation of materials. In the recycling group, packaging materials such as glass bottles, corrugated cardboard, and plastics were recycled, providing there was no contamination with blood or body fluids. Non-infectious waste was also separated from infectious waste. The recycled bags, the non-infectious waste bags, and the infectious waste bags were weighed to the nearest one-half pound. The type, weight, and number of bags were recorded. The results from the two groups were analyzed using a one sided Student's t-test. A p value< 0.05 was considered significant. The results indicated that recycling and proper separating of waste significantly decreased the amount of waste discarded as "contaminated". Because contaminated or infectious waste costs $5.60 per red bag and non-infectious waste costs $0.02 per pound, decreasing both forms of waste is economically attractive to hospitals. The perfusionist can decrease the amount of waste products generated in the operating room that must be either incinerated or disposed of in landfill. Recycling and proper separation of waste significantly decreased the expenditure for waste disposal, and decreased the impact of perfusion services on our environment. Volume 27, Number 2, june 1995 Address all correspondence to: Lisa M. Bliss, RN, BS 68215 Estio Road Cathedral City, CA 92234
منابع مشابه
Improved fluid management by a simple extracorporeal circuit design change.
Extracorporeal circulation (ECC) circuits vary in design in order to fulfill the needs and perfusion plans of the surgical team. There are as many variations in these configurations as there are perfusion techniques. This article describes a simple circuit modification that has diverse advantages in its application. The implementation of this modification may improve sterile technique, lower...
متن کاملClinical experience of a vacuum-assisted nonroller extra-corporeal circulation system.
We designed a nonroller extra-corporeal circulation system (NRECC) to minimize space requirements and to improve the safety and ease of cardiopulmonary bypass. The NRECC includes a circuit, a centrifugal pump, and a vacuum regulator. The vacuum regulator has five channels, each of which can control negative pressure independently. Negative pressure is applied to suctions, a vent, and a venous r...
متن کاملEffect of cardiopulmonary bypass on a patient with endocarditis and malaria.
Knowledge about the effects of cardiopulmonary bypass on malarial patients is scant. Malaria-induced hemolysis can exercerbate by performing extracorporeal circulation on a patient infected with Plasmodium and may, therefore, lead to a critical hemolysis jeopardizing the clinical outcome. A 52-year-old patient suffering from malaria and endocarditis was scheduled for urgent aortic valve replace...
متن کاملClinical outcomes of pulmonary valve replacement surgery in pediatrics: a single-center experience long-term study
Introduction: Heart valve disease in pediatricsis an increasing global concern, especially in developing countries. This study aims to determine the clinical outcomes of pulmonary valve replacement (PVR) surgery in pediatrics. Methods: The authors retrospectively identified all pediatrics undergoing PVR surgery at Imam Reza hospital (Mashhad, Iran) between 2000 and 2020. Their medical records...
متن کاملEvaluation of extracorporeal blood heat exchanger devices.
An accurate and easy to use test circuit has been developed for the performance evaluation of the heat exchangers used in cardiac surgery during extracorporeal circulation. The water part of the heat exchanger is fixed at a flow rate of 15 l/min and at a temperature of 40 degrees C. In the blood side, the flow rate is varied from 1 to 6 l/min and the temperature is 30 degrees C. The use of a pr...
متن کامل