A multiwire microelectrode for single unit recording in deep brain structures.
نویسندگان
چکیده
A method is described by which a single shaft multiwire microelectrode can be fabricated efficiently. The resulting electrode can be attached to a commercial microdrive and used for single neuronal unit recording from one or more tracks in deep brain structures of anesthetized or awake animals. The electrode consists of a 30 gauge stainless steel cannula through which multiple strands of 13 micron insulated tungsten microwires are threaded. At the electrode tip the wires protrude 3-4 mm from the cannula and are cut individually at suitable offsets. The tip is stabilized and fixed to the cannula with cyanoacrylate. At the base of the electrode the wires are threaded through flexible plastic tubing that provides strain relief and are glued to individual pins of a miniature connector that plugs into a field effect transistor (FET) voltage follower. Good single unit recordings have been obtained routinely from the basal ganglia of awake, behaving monkeys with this electrode.
منابع مشابه
Innovative Methodology High-Resolution Three-Dimensional Microelectrode Brain Mapping Using Stereo Microfocal X-ray Imaging
Cox DD, Papanastassiou AM, Oreper D, Andken BB, DiCarlo JJ. High-resolution three-dimensional microelectrode brain mapping using stereo microfocal X-ray imaging. J Neurophysiol 100: 2966–2976, 2008. First published September 24, 2008; doi:10.1152/jn.90672.2008. Much of our knowledge of brain function has been gleaned from studies using microelectrodes to characterize the response properties of ...
متن کاملA cost analysis of intraoperative microelectrode recording during subthalamic stimulation for Parkinson's disease.
Deep brain stimulation of the subthalamic nucleus is the standard of care for treating medically intractable Parkinson's disease. Although the adjunct of microelectrode recording improves the targeting accuracy of subthalamic nucleus deep brain stimulation in comparison with image guidance alone, there has been no investigation of the financial cost of intraoperative microelectrode recording. T...
متن کاملHigh-resolution three-dimensional microelectrode brain mapping using stereo microfocal X-ray imaging.
Much of our knowledge of brain function has been gleaned from studies using microelectrodes to characterize the response properties of individual neurons in vivo. However, because it is difficult to accurately determine the location of a microelectrode tip within the brain, it is impossible to systematically map the fine three-dimensional spatial organization of many brain areas, especially in ...
متن کاملA Multimodal Micro-Optrode Combining Field and Single Unit Recording, Multispectral Detection and Photolabeling Capabilities
Microelectrodes have been very instrumental and minimally invasive for in vivo functional studies from deep brain structures. However they are limited in the amount of information they provide. Here, we describe a, aluminum-coated, fibre optic-based glass microprobe with multiple electrical and optical detection capabilities while retaining tip dimensions that enable single cell measurements (d...
متن کاملStatistical Methods of Analysis and Visualization of Extracellular Microelectrode Recordings
Determining neuronal structures during stereotactic surgery in Parkinsons disease (PD) patients is a prerequisite for optimal placement of deep brain stimulation electrodes and/or neuronal ablation. This study describes statistical signal processing methods that automatically analyze microelectrode recordings and display a neurophysiological brainmap of the stereotactic trajectory. The sponta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of neuroscience methods
دوره 32 2 شماره
صفحات -
تاریخ انتشار 1990