Surveillance of Environmental and Procedural Measures of Infection Control in the Operating Theatre Setting

نویسندگان

  • Laura Dallolio
  • Alessandra Raggi
  • Tiziana Sanna
  • Magda Mazzetti
  • Alessandra Orsi
  • Angela Zanni
  • Patrizia Farruggia
  • Erica Leoni
چکیده

The microbiological contamination of operating theatres and the lack of adherence to best practices by surgical staff represent some of the factors affecting Surgical Site Infections (SSIs). The aim of the present study was to assess the microbiological quality of operating settings and the staff compliance to the SSI evidence-based control measures. Ten operating rooms were examined for microbiological contamination of air and surfaces, after cleaning procedures, in "at rest" conditions. Furthermore, 10 surgical operations were monitored to assess staff compliance to the recommended practices. None of the air samples exceeded microbiological reference standards and only six of the 200 surface samples (3.0%) were slightly above recommended levels. Potentially pathogenic bacteria and moulds were never detected. Staff compliance to best practices varied depending on the type of behaviour investigated and the role of the operator. The major not compliant behaviours were: pre-operative skin antisepsis, crowding of the operating room and hand hygiene of the anaesthetist. The good environmental microbiological quality observed is indicative of the efficacy of the cleaning-sanitization procedures adopted. The major critical point was staff compliance to recommended practices. Awareness campaigns are therefore necessary, aimed at improving the organisation of work so as to facilitate compliance to operative protocols.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compliance With Infection Control Guidelines in the Operating Rooms

Introduction: Compliance with the safety standards in the operating rooms, as one of the most complex work environments in the health care systems, is very important. One of the safety measures is the infection control standard.  Objective: This study aimed to investigate compliance with infection control standards in the operating rooms of teaching hospitals in Rasht City, Iran. Materials an...

متن کامل

به کارگیری اصول کنترل عفونت در کارکنان اتاق عمل بیمارستان های آموزشی و درمانی دانشگاه علوم پزشکی مازندران

Background and purpose: Nosocomial infections are one of the health problems of the present century. The rate of these infections increases by increase in the length of hospital stay and results in high rate of morbidity and mortality and high hospital costs. Moreover, such infections could easily spread in the community. Successful control of nosocomial infections requires appropriate preventi...

متن کامل

Operating theatre quality and prevention of surgical site infections

Surgical site infections (SSI) account for 14% to 17% of all hospital-acquired infections and 38% of nosocomial infections in surgical patients. SSI remain a substantial cause of morbidity and death, possibly because of the larger numbers of elderly surgical patients or those with a variety of chronic and immunocompromising conditions, and emergence of antibiotic-resistant microorganisms. Facto...

متن کامل

تأثیر مدیریت کیفیت بر درآمد بخش اعمال جراحی بیمارستان: گزارش کوتاه

Background: Hospitals are dealing with unlimited demands and limited resources. Hospital managers should use appropriate strategies to improve quality of services, enhance patients’ satisfaction and increase financial resources. This study aimed to examine the impact of quality management. Methods: A participatory action research was used for the intervention on income of operating theatre in ...

متن کامل

Contamination during removal of cement in revision hip arthroplasty. A cadaver study using ultrasound and high-speed cutters.

Instruments used in surgery which rotate or vibrate at a high frequency can produce potentially contaminated aerosols. Such tools are in use in cemented hip revision arthroplasties. We aimed to measure the extent of the environmental and body contamination caused by an ultrasound device and a high-speed cutter. On a human cadaver we carried out a complete surgical procedure including draping an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2017