Spline Based Inhomogeneity Correction for 11C-PIB PET Segmentation Using Expectation Maximization
نویسندگان
چکیده
With the advent of biomarkers such as 11C-PIB and the increase in use of PET, automated methods are required for processing and analyzing datasets from research studies and in clinical settings. A common preprocessing step is the calculation of standardized uptake value ratio (SUVR) for inter-subject normalization. This requires segmented grey matter (GM) for VOI refinement. However 11C-PIB uptake is proportional to amyloid build up leading to inhomogeneities in intensities, especially within GM. Inhomogeneities present a challenge for clustering and pattern classification based approaches to PET segmentation as proposed in current literature. In this paper we modify a MR image segmentation technique based on expectation maximization for 11C-PIB PET segmentation. A priori probability maps of the tissue types are used to initialize and enforce anatomical constraints. We developed a Bézier spline based inhomogeneity correction techniques that is embedded in the segmentation algorithm and minimizes inhomogeneity resulting in better segmentations of 11C-PIB PET images. We compare our inhomogeneity with a global polynomial correction technique and validate our approach using co-registered MRI segmentations.
منابع مشابه
Quantification and accuracy of clinical [11C]-PiB PET/MRI: the effect of MR-based attenuation correction
The Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Denmark The Dixon-Water-Fat segmentation (DWFS) method is a standard attenuation correction (AC) method in PET/MRI on the Siemens mMR and has demonstrated a systematic quantitative bias in [18F]-FDG-PET/MRI studies of the brain compared to PET/CT. The aim of this study was to evaluate the impact of DWFS-AC in a hyb...
متن کاملDirect and Indirect Surface Coil Correction for Cardiac Perfusion MRI
Introduction Although the first-pass myocardial perfusion MRI has proven its effectiveness in the diagnosis of ischemic heart disease, this technique is still not routinely used. Certain technical difficulties prevent perfusion MRI from being added into the clinical workflow, including complex cardiac motion, limited imaging time, and B1-field inhomogeneity caused by non-uniform characteristics...
متن کاملThe feasibility of 11C‐PIB‐PET/CT for amyloid plaque burden: validation of the effectiveness of CT‐based partial volume correction
INTRODUCTION Amyloid positron-emission tomography (PET) imaging with 11C-Pittsburgh compound B (PiB) is an effective tool for assessing brain amyloid deposits. PET imaging, however, can suffer from the partial volume effect (PVE). PVE has been corrected using MRI (magnetic resonance imaging) image data. However, correction of the PVE of PET using MRI usually requires two separate procedures, im...
متن کاملCharacterization of PiB binding to white matter in Alzheimer disease and other dementias.
UNLABELLED 11C-Pittsburgh Compound B (11C-PiB) PET has demonstrated significantly higher PiB retention in the gray matter of Alzheimer disease (AD) patients than in healthy controls (HCs). PiB is similarly retained within the white matter of HC and AD brains. Although the specificity of PiB for Abeta plaques in gray matter has been well described, the nature of PiB binding to white matter remai...
متن کاملImpact of spillover from white matter by partial volume effect on quantification of amyloid deposition with [11C]PiB PET
High non-specific uptake of [11C]Pittsburgh compound B ([11C]PiB) in white matter and signal spillover from white matter, due to partial volume effects, confound radioactivity measured in positron emission tomography (PET) with [11C]PiB. We aimed to reveal the partial volume effect in absolute values of kinetic parameters for [11C]PiB, in terms of spillover from white matter. Dynamic data acqui...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
دوره 10 Pt 1 شماره
صفحات -
تاریخ انتشار 2007