Thromboembolic Events Associated with Electrolytic Detachment of Guglielmi Detachable Coils and Target Coils : Comparison with Use of Diffusion-Weighted MR Imaging

نویسندگان

  • Myeong Jin Kim
  • Yong Cheol Lim
  • Se-yang Oh
  • Byung Moon Kim
  • Bum-soo Kim
  • Yong Sam Shin
چکیده

OBJECTIVE The purpose of this study was to retrospectively evaluate and compare the incidence of diffusion-weighted image (DWI) lesions between the Guglielmi detachable coil (GDC) and the Target coil for treating unruptured intracranial aneurysm. METHODS From 2010 to 2011, consecutive 222 patients with an intracranial aneurysm underwent coil embolization. Inclusion criterias were : 1) unruptured intracranial aneurysm, 2) one or more GDC or Target coils used with or without other coils, 3) DWI examination within 24 hours after coiling, and 4) coiling performed without a balloon or stent. RESULTS Ninety patients (92 cases) met the inclusion criteria. DWI lesions were detected in 55 (61.1%) of 90 patients. In the GDC group (n=44), DWI lesions were detected in 31 (70.5%). The average number of DWI lesions was 5.0±8.7 (mean±SD; range, 1-40) in aneurysm-related territory. In the Target coil group (n=48), DWI lesions were detected in 24 (50.0%). The number of DWI lesion was 2.1±5.4 (range, 1-32) in aneurysm-related territory. There was no significant correlation between a number of coils and DWI lesions. No significant differences were also observed in the number of DWI lesions in each group. CONCLUSION The GDC and Target coils, which have an electrolytic detachable system, showed no differences in the incidence of DWI lesion.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gas generation and clot formation during electrolytic detachment of Guglielmi detachable coils: in vitro observations and animal experiment.

BACKGROUND AND PURPOSE Recent reports describe a high rate of thromboembolic events related to Guglielmi detachable coil (GDC) use in the treatment of cerebral aneurysms. The purpose of this study was to investigate electrolysis-related changes of blood as a potential cause of thromboembolic complications associated with GDC use. METHODS For in vitro observations, 15 GDCs (10 conventional coi...

متن کامل

Silent thromboembolic events associated with the treatment of unruptured cerebral aneurysms by use of Guglielmi detachable coils: prospective study applying diffusion-weighted imaging.

BACKGROUND AND PURPOSE Aneurysm embolization using Guglielmi detachable coils (GDC) is gaining increasing acceptance as a viable alternative to surgery in the treatment of cerebral aneurysms. Although recent reports describe a significant rate of symptomatic thromboembolic complications with GDC use, many of the neurologic deficits are transient. We sought to determine the incidence of silent t...

متن کامل

Cerebral aneurysms treated by Guglielmi detachable coils: evaluation with diffusion-weighted MR imaging.

BACKGROUND AND PURPOSE The most frequent and serious complications of endovascular treatment of intracranial aneurysms with Guglielmi detachable coils (GDCs) are ischemic lesions caused by thromboembolic events. Diffusion-weighted MR imaging appears to be the most sensitive technique for detecting early ischemic phenomena. We evaluated this technique for the detection of brain changes in patien...

متن کامل

Thromboembolic events associated with balloon-assisted coil embolization: evaluation with diffusion-weighted MR imaging.

BACKGROUND AND PURPOSE Thromboembolic events may occur during or after the treatment of intracranial aneurysms with Guglielmi detachable coils (GDCs). The purpose of this study was to determine the frequency of thromboembolic events associated with balloon-assisted coil placement and to investigate possible risk factors for these events during balloon-assisted coil placement and embolization. ...

متن کامل

MR artifacts, heat production, and ferromagnetism of Guglielmi detachable coils.

The Guglielmi detachable coil, a platinum microcoil used in the endovascular treatment of intracranial aneurysms, was studied in vitro for its MR imaging artifacts, heat production, and ferromagnetism. In addition, imaging artifacts were studied in vivo in eight patients who had undergone therapeutic placement of these coils. These devices displayed a very low level of MR artifact and no ferrom...