Demonstration of supernumerary tracheal bronchus by computed tomographic scanning and magnetic resonance imaging.
نویسندگان
چکیده
A bronchus arising directly from the trachea is an infrequent congenital anomaly which usually represents the displaced origin of a normal bronchus. Rarely, a true supernumerary tracheal bronchus occurs supplying an associated tracheal lobe. The case is described of a patient in whom a supernumerary tracheal bronchus and tracheal lobe was demonstrated by computed tomographic scanning and magnetic resonance imaging.
منابع مشابه
Bimodal magnetic resonance imaging-computed tomography nanoprobes: A Review
Bimodal imaging combines two imaging modalities in order to benefit from their advantages and compensate the limitations of each modality. This technique could accurately detect diseases for diagnostic purposes. Nanoparticles simultaneously offer diagnostic data via various imaging modalities owing to their unique properties. Moreover, bimodal nanoprobes could be incorporated into theranostic s...
متن کاملTracheal Bronchus: High Resolution Computed Tomography diagnosis in a symptomatic patient.
A 75-year-old female underwent a High Resolution Computed Tomography (HRCT) scan for recurrent bronchitis and cough. HRCT images showed an anomalous supernumerary bronchus to the right upper lobe directly arising from the right side of distal trachea, corresponding to Tracheal Bronchus (TrB). TrB can cause recurrent right upper lobe pneumonia and special care is requiring during endotracheal in...
متن کاملPartial lung resection of supernumerary tracheal bronchus combined with pulmonary artery sling in an adult: report of a case.
An adult case of pulmonary resection for repeated infections in a supernumerary tracheal bronchus combined with a pulmonary artery sling is reported. A 33-year-old woman with a pulmonary artery sling was referred for recurrent lung infections. Chest computed tomography showed the left pulmonary artery arising from the right pulmonary artery and coursing posterior to the trachea. The lung parenc...
متن کاملArtifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging
Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...
متن کاملGenerating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method
Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 50 4 شماره
صفحات -
تاریخ انتشار 1995