Performance of Paracheck™-Pf, SD Bioline malaria Ag-Pf and SD Bioline malaria Ag-Pf/pan for diagnosis of falciparum malaria in the Central African Republic

نویسندگان

  • Djibrine Djallé
  • Jean Chrysostome Gody
  • Jean Methode Moyen
  • Gaspard Tekpa
  • Julienne Ipero
  • Nestor Madji
  • Sébastien Breurec
  • Alexandre Manirakiza
چکیده

BACKGROUND Rapid diagnostic tests (RDTs) are the current complement to microscopy for ensuring prompt malaria treatment. We determined the performance of three candidate RDTs (Paracheck™-Pf, SD Bioline malaria Ag-Pf and SD Bioline malaria Ag-Pf/pan) for rapid diagnosis of malaria in the Central African Republic. METHODS Blood samples from consecutive febrile patients who attended for laboratory analysis of malaria at the three main health centres of Bangui were screened by microscopy and the RDTs. Two reference standards were used to assess the performance of the RDTs: microscopy and, a combination of microscopy plus nested PCR for slides reported as negative, on the assumption that negative results by microscopy were due to sub-patent parasitaemia. RESULTS We analysed 436 samples. Using the combined reference standard of microscopy + PCR, the sensitivity of Paracheck™-Pf was 85.7% (95% CI, 80.8-89.8%), that of SD Bioline Ag-Pf was 85.4% (95% CI, 80.5-90.7%), and that of SD Bioline Ag-Pf/pan was 88.2% (95% CI, 83.2-92.0%). The tests performed less well in cases of low parasitaemia; however, the sensitivity was > 95% at > 500 parasites/μl. CONCLUSIONS Overall, SD Bioline malaria Ag-Pf and SD Bioline malaria Ag-Pf/pan performed slightly better than Paracheck™-Pf. Use of RDTs with reinforced microscopy practice and laboratory quality assurance should improve malaria treatment in the Central African Republic.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Performance Evaluation of the Sd Bioline Malaria Antigen Ag Pf/pan Test (05fk60) in a Malaria Endemic Area of Southern Ethiopia

Rapid diagnostic tests (RDTs) capable of detecting and differentiating Plasmodium species are needed in areas in which microscopy is unsuitable. This study was conducted to assess the diagnostic performance of the rapid test kit - SD BIOLINE Malaria Ag Pf/Pan(r) (05FK60) in an endemic area. Microscopy of Giemsa-stained blood films were performed to detect and estimate the Plasmodium density in ...

متن کامل

Evaluation of two new immunochromatographic assays for diagnosis of malaria.

We assessed the performance of two new commercially available rapid diagnostic tests (RDTs) for malaria (SD Bioline Malaria Ag Pf test and Ag Pf/Pan test) in 200 patients with uncomplicated malaria between August and October 2007 in Madagascar. Results of the two RDTs were compared with those obtained by microscopy and real-time polymerase chain reaction. The sensitivity and specificity for det...

متن کامل

Performance of SD Bioline Malaria Ag Pf/Pan rapid test in the diagnosis of malaria in South-Kivu, DR Congo

INTRODUCTION Use of malaria rapid diagnostic tests (RDTs) has improved the management of this disease. We evaluated the validity of the SD-Bioline Malaria-Ag-Pf/Pan™ (Batch 60952) RDT supplied by the Malaria Control Program of the DRCongo. METHODS cChildren (n = 460) aged below 5 years seen in curative care (CC) for suspected malaria and in pre-school consultation (PSC) in two rural centers u...

متن کامل

Field Performance of Wondfo and SD Bioline Malaria Pf/Pan Rapid Diagnostic Tests for Malaria Diagnosis in Koraput District, Odisha State, India

Rapid diagnostic tests (RDTs) have now been recommended and brought to field operation by the National Vector Borne Disease Control Programme (NVBDCP). The objective of this study was to evaluate the performance of two commonly used RDTs; Wondfo and SD Bioline Malaria Pf/Pan for malaria diagnosis in an endemic area of Koraput district, Odisha state. A total of 100 clinically suspected malaria p...

متن کامل

Evaluation of Rapid Diagnostics for Plasmodium falciparum and P. vivax in Mae Sot Malaria Endemic Area, Thailand

Prompt and accurate diagnosis of malaria is the key to prevent disease morbidity and mortality. This study was carried out to evaluate diagnostic performance of 3 commercial rapid detection tests (RDTs), i.e., Malaria Antigen Pf/Pan™, Malaria Ag-Pf™, and Malaria Ag-Pv™ tests, in comparison with the microscopic and PCR methods. A total of 460 blood samples microscopically positive for Plasmodium...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014