Automation of liquid-liquid extraction-spectrophotometry using prolonged pseudo-liquid drops and handheld CCD for speciation of Cr(VI) and Cr(III) in water samples.
نویسندگان
چکیده
A simple spectrophotometric system, based on a prolonged pseudo-liquid drop device as an optical cell and a handheld charge coupled device (CCD) as a detector, was constructed for automatic liquid-liquid extraction and spectrophotometric speciation of trace Cr(VI) and Cr(III) in water samples. A tungsten halogen lamp was used as the light source, and a laboratory-constructed T-tube with two open ends was used to form the prolonged pseudo-liquid drop inside the tube. In the medium of perchloric acid solution, Cr(VI) reacted with 1,5-diphenylcarbazide (DPC); the formed complex was automatically extracted into n-pentanol, with a preconcentration ratio of about 5. The organic phase with extracted chromium complex was then pumped through the optical cell for absorbance measurement at 548 nm. Under optimal conditions, the calibration curve was linear in the range of 7.5 - 350 microg L(-1), with a correlation coefficient of 0.9993. The limit of detection (3sigma) was 7.5 microg L(-1). That Cr(III) species cannot react with DPC, but can be oxidized to Cr(VI) prior to determination, is the basis of the speciation analysis. The proposed speciation analysis was sensitive, yet simple, labor-effective, and cost-effective. It has been preliminarily applied for the speciation of Cr(VI) and Cr(III) in spiked river and tap water samples. It can also be used for other automatic liquid-liquid extraction-spectrophotometric determinations.
منابع مشابه
Preconcentration and Speciation of Chromium Using Dispersive Liquid-Liquid Microextraction; Application to Milk and Different Water Samples
A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) was developed for determination and speciation of trace amounts of chromium (Cr) by flame atomic absorption spectrometry (FAAS). In the proposed approach, chloroform and methanol were used as extraction and dispersive solvents. A new Schiff's base ligand, bis(2-methoxy benzaldehyde) ethylene d...
متن کاملChromium redox speciation in food samples
Chromium is an element with important biological characteristics, depending on its different species. Cr(III) is considered as essential; however, the Cr(VI) form is classified as carcinogenic. For this reason, speciation analysis in food samples is a very important question. The proposed data procedures for chromium redox speciation in the literature can be divided into those with the use of o...
متن کاملUltra-Trace Determination of Silver in Water, Soil and Radiology Film Samples Using Dispersive Liquid-Liquid Microextraction and Microvolume UV–Vis Spectrophotometry
In this research, a Dispersive Liquid-Liquid MicroExtraction (DLLME) method coupled to UV-vis spectrophotometry was developed for the indirect determination of silver ion. The method is based on the catalytic effect of the silver ion on the oxidation of congo red by potassium peroxodisulphate and extraction with DLLME procedure using chloroform (extraction solvent) containing cetyltrimethyl...
متن کاملSpeciation of chromium metal ions by RP-HPLC.
A high-performance liquid chromatographic method with UV detection, based on chelation with morpholine-4-carbodithioate (MDTC), has been developed for the speciation of chromium. Simultaneous preconcentration of Cr(III) and Cr(VI) in aqueous solutions was achieved by extraction of metal species in chloroform as MDTC complexes. The separation of MDTC chelates of Cr(III) and Cr(VI) was realized o...
متن کاملA Study on the Removal of Chromium(VI) Oxanions from Acid Solutions by Using Oxonium Ion-Crown Ether Complexes as Mobile Carrier Agents
Crown ethers 12-crown-4 (12C4), benzo-15-crown-5 (B15C5), 18-crown-6 (18C6), nitrobenzo-18-crown-6 (NB18C6) dibenzo-18-crown-6 (DB18C6) and dicyclohexyl-18-crown-6 (DC18C6), dissolved in dichloromethane, are able to form oxonium-ion complexes in contact with aqueous sulfuric and hydrochloric acid solutions. This ability allows the transfer of Cr(VI) oxanions from the acid media, through an ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 21 10 شماره
صفحات -
تاریخ انتشار 2005