Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients.
نویسندگان
چکیده
OBJECTIVE To determine whether noninvasive hemoglobin measurement by Pulse CO-Oximetry could provide clinically acceptable absolute and trend accuracy in critically ill patients, compared to other invasive methods of hemoglobin assessment available at bedside and the gold standard, the laboratory analyzer. DESIGN Prospective study. SETTING Surgical intensive care unit of a university teaching hospital. PATIENTS Sixty-two patients continuously monitored with Pulse CO-Oximetry (Masimo Radical-7). INTERVENTIONS None. MEASUREMENTS AND RESULTS Four hundred seventy-one blood samples were analyzed by a point-of-care device (HemoCue 301), a satellite lab CO-Oximeter (Siemens RapidPoint 405), and a laboratory hematology analyzer (Sysmex XT-2000i), which was considered the reference device. Hemoglobin values reported from the invasive methods were compared to the values reported by the Pulse CO-Oximeter at the time of blood draw. When the case-to-case variation was assessed, the bias and limits of agreement were 0.0±1.0 g/dL for the Pulse CO-Oximeter, 0.3±1.3g/dL for the point-of-care device, and 0.9±0.6 g/dL for the satellite lab CO-Oximeter compared to the reference method. Pulse CO-Oximetry showed similar trend accuracy as satellite lab CO-Oximetry, whereas the point-of-care device did not appear to follow the trend of the laboratory analyzer as well as the other test devices. CONCLUSION When compared to laboratory reference values, hemoglobin measurement with Pulse CO-Oximetry has absolute accuracy and trending accuracy similar to widely used, invasive methods of hemoglobin measurement at bedside. Hemoglobin measurement with pulse CO-Oximetry has the additional advantages of providing continuous measurements, noninvasively, which may facilitate hemoglobin monitoring in the intensive care unit.
منابع مشابه
Accuracy of noninvasive and continuous hemoglobin measurement by pulse co-oximetry during preoperative phlebotomy.
BACKGROUND In recent years, the continuous noninvasive hemoglobin measurement has been offered by devices using advanced pulse oximetry technology. Accuracy has been established in healthy adults as well as in surgical and intensive care unit patients but not in the setting of acute hemorrhage. In this study, we evaluated the accuracy of such a device in the clinical setting of preoperative phl...
متن کاملNoninvasive blood pressure monitoring.
For more 20 years, noninvasive blood pressure (NIBP) monitors have been widely used in operating rooms and critical care units to closely monitor blood pressure in patients of all ages. Despite the widespread use of automated blood pressure monitors, clinicians continue to deliberate over the accuracy and reliability of automated NIBP devices compared to other methods of blood pressure determin...
متن کاملInvasive versus noninvasive hemoglobin measurement by pulse CO-Oximeter in neonates admitted to NICU
Background Total haemoglobin measurement (tHb) is one of the most commonly performed laboratory tests in patients admitted to the neonatal intensive care unit (NICU). Non invasive haemoglobin measurement is possible. In neonates this method can reduce iatrogenic blood loss. Studies performed in adults to compare haemoglobin (Hb) obtained with the use of non-invasive Hb monitor and laboratory me...
متن کاملDesign and Implementation of a Fuzzy Intelligent System for Predicting Mortality in Trauma Patients in the Intensive Care Unit
Introduction: The intensive care unit is one of the most costly parts of the national health sector. These costs are largely attributable to the length of stay in the intensive care unit. For this reason, there are significant benefits in predicting patients' length of stay and the percentage of deaths in intensive care units. Therefore, in this study, a fuzzy logic based intelligent system was...
متن کاملAccuracy of a subcutaneous continuous glucose monitor compared with an intravenous continuous glucose monitor in an intensive care unit
Introduction Blood glucose management is important in the intensive care unit (ICU). Although we have used an intravenous continuous glucose monitor for blood glucose management to avoid hypoglycemia, there has been a problem with interruption of blood glucose measurement caused by blood removal failure [1]. A previous study reported that a subcutaneous continuous glucose monitor was reliable f...