High-pressure pulsatile lavage irrigation of fresh intraarticular fractures: effectiveness at removing particulate matter from bone.

نویسندگان

  • Eric W Lee
  • Douglas R Dirschl
  • Gregory Duff
  • Laurence E Dahners
  • Theodore Miclau
چکیده

OBJECTIVE To determine the effectiveness of high-pressure pulsatile lavage (HPL) versus bulb syringe (BS) irrigation in removing particulate matter from metaphyseal cancellous bone. DESIGN Four grams of particulate graphite were placed in twenty distal femoral intraarticular osteotomies performed on New Zealand rabbit hind limbs. Two groups of ten specimens were then irrigated using either HPL or BS irrigation. A representative coronal section from each specimen was then prepared for histologic evaluation using 400x light microscopy. The number and distribution of graphite particles-present as small (less than 20 micrometers), medium (20 to 50 micrometers), and large (greater than 50 micrometers) aggregates-were then recorded. RESULTS The mean maximum perpendicular distance of graphite aggregates of all sizes from the osteotomy site was 12.4 millimeters (+/-SD 2.5) in the HPL group and 12.5 millimeters (+/-SD 2.0) in the BS group (p > 0.5). The mean number of aggregates within four 400x fields (1.08 millimeters) of the osteotomy site was 21.9 (+/-SD 22.0) in the HPL group and 21.8 (+/-SD 27.5) in the BS group (p > 0.5). The mean total number of aggregates in the area surveyed was 129.4 (+/-SD 79.6) in the HPL group and 137.5 (+/-SD 113.6) in the BS group (p > 0.5). Separate analyses controlling for aggregate size of the specimens also revealed no significant differences between HPL and BS irrigation. CONCLUSION HPL and BS irrigation appear equally effective in removing particulate matter from metaphyseal cancellous bone in an intraarticular fracture model. Furthermore, HPL does not appear to drive particulate matter farther into metaphyseal cancellous bone than BS irrigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of Aerosol Particulate Production Between Hydrosurgery, Pressurized Pulsatile, and Bulb Syringe Lavage During Irrigation of Fracture Implants

INTRODUCTION: Surgical site infection can occur after internal fixation of both open and closed fractures following internal fixation. Common methods of infection management include operative debridement and wound irrigation with a bulb syringe, or pressurized pulsatile lavage. The Versajet hydrosurgery tool appears to be an effective tool for debridement. Arecent study found that the Versajet ...

متن کامل

High-pressure irrigation increases adipocyte-like cells at the expense of osteoblasts in vitro.

High-pressure lavage produces greater visible damage to bone at a macroscopic and microscopic level when compared with low-pressure lavage and can result in delay in the healing of fractures. Osteoblasts and adipocytes are derived from mesenchymal stem cells. Conditions which lead to bone loss often involve a switch from the osteoblast to adipocyte lineage. We have therefore examined the effect...

متن کامل

Prevention of Contamination During Pulsatile Lavage Irrigation (printer-friendly)

and Introduction Abstract Pulsatile lavage is a high-pressure irrigation treatment commonly used in the debridement of wounds. The risk of exposure to bloodborne pathogens and contaminants using high-pressure irrigation has been well documented in the literature. Projectile droplets and aerosolized fine droplets may form and spread, potentially contaminating the treatment facility and infecting...

متن کامل

Comparison of irrigation solutions and devices in a contaminated musculoskeletal wound survival model.

BACKGROUND There is much to learn about the effectiveness of different methods currently used for the irrigation of open wounds. The purpose of this study was to compare various approaches in a survival animal model. METHODS We used an established goat model involving the creation of a reproducible complex musculoskeletal wound followed by inoculation with Pseudomonas aeruginosa (lux) bacteri...

متن کامل

Comparing the speed of irrigation between pulsatile lavage versus gravity irrigation: an Ex-vivo experimental investigation

BACKGROUND The need for reoperation or wound infection treatments between pulsatile and gravity irrigation are statistically equivalent, however, it is unclear which method maximizes operative efficiency and expeditious irrigation. In this study we set out to determine the differences in irrigation rate between these various treatment methods. METHODS This was an ex-vivo experimental laborato...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic trauma

دوره 16 3  شماره 

صفحات  -

تاریخ انتشار 2002