Magnetic fluctuation probe design and capacitive pickup rejection
نویسندگان
چکیده
In this article the capacitive pickup of magnetic fluctuation probes for plasma applications is studied. The nine most commonly used probe designs are compared with respect to their capacitive pickup rejection, magnetic sensitivity, and minimum plasma disturbance. For absolute calibration, well defined electric and magnetic field fluctuations are produced separately in a Faraday cup and in a Helmholtz magnetic field coil configuration, respectively. A sample measurement in a radio frequency helicon plasma demonstrates that the optimum probe design is well suited for measuring magnetic fluctuations in a plasma environment. © 2002 American Institute of Physics. @DOI: 10.1063/1.1512341#
منابع مشابه
A simple miniature magnetic probe with inherent electrostatic rejection
Inductive magnetic probes are often used to measure oscillating magnetic fields in plasma.r3 The sensitivity of a magnetic probe to electrostatic potentials (“capacitive pickup”) is usually an important consideration. Centertapped construction of such a probe, shown in Fig. 1 (b), helps to minimize capacitive pickup with respect to a simply wound probe [Fig. 1 (a)]. This relies on the fact that...
متن کاملHigh sensitive vectorial B-probe for low frequency plasma waves.
A miniaturized multidimensional magnetic probe is developed for application in a low-temperature plasma environment. A very high sensitivity for low-frequency magnetic field fluctuations with constant phase run, a very good signal-to-noise ratio combined with an efficient electrostatic pickup rejection, renders the probe superior compared with any commercial solution. A two-step calibration all...
متن کاملDesign, construction, and calibration of a three-axis, high-frequency magnetic probe (B-dot probe) as a diagnostic for exploding plasmas.
A three-axis, 2.5 mm overall diameter differential magnetic probe (also known as B-dot probe) is discussed in detail from its design and construction to its calibration and use as diagnostic of fast transient effects in exploding plasmas. A design and construction method is presented as a means to reduce stray pickup, eliminate electrostatic pickup, reduce physical size, and increase magnetic s...
متن کاملProbes for measuring fluctuation-induced Maxwell and Reynolds stresses in the edge of the Madison Symmetric Torus reversed field pinch.
Several probes have been constructed to measure fluctuation-induced Maxwell and Reynolds stresses in the edge of the Madison Symmetric Torus reversed field pinch (RFP). The magnetic probe is composed of six magnetic pickup coil triplets. The triplets are separated spatially, which allows for local measurements of the Maxwell stress. To measure the plasma flow components for evaluation of the Re...
متن کاملA Fast Injection Kicker Magnet for the Tevatron
A new proton injection kicker system is required for the Tevatron in the Run II era. The new system was designed to supply 1.25 kG-m into a magnetic aperture of 48 mm vertical x 71 mm horizontal x 5 m long with a 396 ns bunch spacing. The system is configured to be upgraded to a bunch spacing of 132 ns with additional pulsed power supplies. The design of the magnet incorporated some novel featu...