Differentiating Keratoconus and Corneal Warpage by Analyzing Focal Change Patterns in Corneal Topography, Pachymetry, and Epithelial Thickness Maps

نویسندگان

  • Maolong Tang
  • Yan Li
  • Winston Chamberlain
  • Derek J. Louie
  • Julie M. Schallhorn
  • David Huang
چکیده

PURPOSE To differentiate between keratoconus and contact lens-related corneal warpage by combining focal change patterns in anterior corneal topography, pachymetry, and epithelial thickness maps. METHODS Pachymetry and epithelial thickness maps of normal, keratoconus, and warpage, and forme fruste keratoconus (FFK) eyes were obtained from a Fourier-domain optical coherence tomography (OCT). Epithelial pattern standard deviation (PSD) was calculated and combined with two novel indices, the Warpage Index and the Anterior Ectasia Index, to differentiate between normal, keratoconus, and warpage eyes. The values of the three parameters were compared between groups. RESULTS The study included 22 normal, 31 keratoconic, 11 warpage, and 8 FFK eyes. The epithelial PSD was normal (< 0.041) for 100% normal eyes and abnormal (> 0.041) for 100% of keratoconic eyes, 81.8% of warpage eyes, and 87.5% of FFK eyes. The Anterior Ectasia Index of normal eyes (1.66 ± 0.74) was significantly lower than that for the keratoconus eyes (17.5 ± 7.17), the warpage eyes (2.98 ± 1.69), and the FFK eyes (6.95 ± 5.86). The Warpage Index was positive in all warpage eyes and negative for all keratoconic and FFK eyes except three wearing rigid gas-permeable contact lens. CONCLUSIONS The epithelial PSD can distinguish normal from keratoconus or warpage, but does not distinguish between these two conditions. The Anterior Ectasia Index is abnormal in keratoconus but not warpage. The Warpage Index is positive for warpage and negative for keratoconus, except in cases where keratoconus and warpage coexist. Together, the three parameters are strong tripartite discriminators of normal, keratoconus, and warpage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

One-year Outcomes of Pachymetry and Epithelium Thicknesses after Accelerated (45 mW/cm2) Transepithelial Corneal Collagen Cross-linking for Keratoconus Patients

The thickness of corneal pachymetry and the epithelium after accelerated (45 mW/cm(2)) transepithelial corneal collagen cross-linking (CXL) for keratoconus were assessed in this prospective case series study. Twenty-eight patients were treated for keratoconus. The mean Kmax was 56.18 ± 7.90. The thinnest point, as assessed by optical coherence tomography (OCT), was 443.18 ± 39.75 μm. Accelerate...

متن کامل

Keratoconus detection using corneal topography.

UNLABELLED PURPOSETo review the topographic patterns associated with keratoconus suspects and provide criteria for keratoconus screening. METHODS Case study using maps from the NIDEK OPD-Scan II and OPD Station to highlight patterns seen in keratoconic corneas. RESULTS Five criteria are listed for the detection of keratoconus: 1) apex of the cone is not centered at the 6-o'clock semi-meridi...

متن کامل

Automated keratoconus screening with corneal topography analysis.

PURPOSE Although visual inspection of corneal topography maps by trained experts can be powerful, this method is inherently subjective. Quantitative classification methods that can detect and classify abnormal topographic patterns would be useful. An automated system was developed to differentiate keratoconus patterns from other conditions using computer-assisted videokeratoscopy. METHODS Thi...

متن کامل

Prevalence of Keratoconus and Subclinical Keratoconus in Subjects with Astigmatism Using Pentacam Derived Parameters

PURPOSE To determine the prevalence of keratoconus (KCN) and subclinical KCN among subjects with two or more diopters (D) of astigmatism, and to compare Pentacam parameters among these subjects. METHODS One hundred and twenty eight eyes of 64 subjects with astigmatism ≥2D were included in the study. All subjects underwent a complete ophthalmic examination which included refraction, visual acu...

متن کامل

Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography

Purpose. To compare the characteristics of asymmetric keratoconic eyes and normal eyes by Fourier domain optical coherence tomography (OCT) corneal mapping. Methods. Retrospective corneal and epithelial thickness OCT data for 74 patients were compared in three groups of eyes: keratoconic (n = 22) and normal fellow eyes (n = 22) in patients with asymmetric keratoconus and normal eyes (n = 104) i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 57  شماره 

صفحات  -

تاریخ انتشار 2016