Transfixed condylar plate (TCP) provides better biomechanical and weight bearing possibilities for the fixation of trochanteric fracture.

نویسندگان

  • Josip Turcić
  • Ivan Dobrić
  • Tonisav Antoljak
چکیده

The goal of this research was to find the implant which would provide a better possibility of the fractured osteoporotic bone weight bearing after trochanteric fracture fixation. The authors constructed a new implant based on the conventional condylar plate, as part of a stabile triangular system. Because of the special oblique form of the screw which absolutely stabilizes vertical and horizontal arm of the plate, this plate was named the transfixed condylar plate (TCP). Analysis showed 6 kN of tolerant loading elastic in TCP with a longer horizontal arm, while this value in the conventional condylar plate was 2.5 kN. Also, dynamic resistance was 2.4 times higher in TCP then in the control model. These improved biomechanical results of this plating fixation system are expected to be found in the clinical use of this plate. This would enhance an early rehabilitation and a better functional outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Titanium Elastic Nail (TEN) versus Reconstruction Plate Repair of Midshaft Clavicular Fractures: A Finite Element Study

BACKGROUND The biomechanical characteristics of midshaft clavicular fractures treated with titanium elastic nail (TEN) is unclear. This study aimed to present a biomechanical finite element analysis of biomechanical characteristics involved in TEN fixation and reconstruction plate fixation for midshaft clavicular fractures. METHODS Finite element models of the intact clavicle and of midshaft ...

متن کامل

Fixation systems of greater trochanteric osteotomies: biomechanical and clinical outcomes.

The development of cerclage systems for fixation of greater trochanteric osteotomies has progressed from monofilament wires to multifilament cables to cable grip and cable plate systems. Cerclage wires and cables have various clinical indications, including fixation for fractures and for trochanteric osteotomy in hip arthroplasty. To achieve stable fixation and eventual union of the trochanteri...

متن کامل

Fixation of Supracondylar Femoral Fractures: a Biomechanical Analysis Comparing 95° Blade Plates and Dynamic Condylar Screws (dcs)

OBJECTIVE To determine, by means of comparative biomechanical tests, whether greater compressive load resistance and flexion is presented by 95° angled blade plates or by dynamic condylar screws (DCS), and to correlate the failure type presented during the tests with each type of plate. METHODS Sixty-five porcine femurs were subjected to 1 cm medial wedge osteotomy, in the metaphysis, to simu...

متن کامل

Biomechanical Comparison of Two Ludloff Metatarsal Osteotomy Fixations: Compression Screws vs. Locking Plate

BACKGROUND: Ludloff osteotomy fixation with compression screws has been widely used in the treatment of Hallux Valgus deformities [1, 2]. Generally six weeks of non-weight-bearing is required postoperatively to allow bone union. Besides the significant inconvenience due to non-weight-bearing, noncompliance may induce malunion, nonunion and loss of correction, indicating screw fixation is not st...

متن کامل

Biomechanical Benefits of the VariAx Distal Lateral Fibula Plate

Distal fibula fractures are the most common injury of weight bearing bones. Several studies have shown the benefit of locking plates especially in osteoporotic bone. The aim of this biomechanical study was to test the anatomically shaped VariAx Distal Lateral Fibula Plate in comparison to a commonly used 1/3 Tubular Plate. The implants were assembled to bone surrogates simulating a comminuted f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Collegium antropologicum

دوره 32 4  شماره 

صفحات  -

تاریخ انتشار 2008