Refractive shifts in four selected artificial vitreous substitutes based on Gullstrand-Emsley and Liou-Brennan schematic eyes.
نویسندگان
چکیده
PURPOSE To determine and compare the refractive shifts based on Gullstrand-Emsley and Liou-Brennan schematic eyes after filling them with four selected artificial vitreous substitutes: silicone oil, heavy silicone oil, hydrogels, and encapsuled balanced salt solution. METHODS The optical constants of artificial vitreous body-filled eyes were calculated based on Gullstrand-Emsley and Liou-Brennan schematic eyes with accommodation relaxed. The theoretical refractive shifts in these two models were compared in pars plana vitrectomy (PPV), PPV plus lensectomized and PPV plus intraocular lens (IOL) eyes after four artificial vitreous tamponades. RESULTS The Gullstrand-Emsley schematic eye shows refractive shifts of +8.710, -4.544, +1.136, and -0.338 D in PPV eyes; +11.044, +20.332, +16.351, and +17.413 D in PPV plus lensectomized eyes; and the need for IOL powers of +22.195, +22.366, +22.292, and +22.312 D in PPV plus IOL eyes in silicone oil, heavy silicone oil, hydrogels, and encapsuled balanced salt solution tamponade eyes, respectively. Similarly, the Liou-Brennan schematic eye induced shifts of +6.260, -3.266, +0.817, and -0.272 D in PPV eyes; +13.181, +20.654, +17.451, and +18.305 D in PPV plus lensectomized eyes; and the need IOL powers of +13.522, +23.767, +19.389, and +20.558 D in PPV plus IOL eyes, respectively. CONCLUSIONS The Gullstrand-Emsley schematic eye is a convenient and accurate model for predicting refractive shifts for hydrogels and encapsuled balanced salt solution substitutes in PPV eyes. The Liou-Brennan schematic eye is recommended for silicone oil and heavy silicone oil in PPV eyes and for all four substitutes in PPV plus lensectomized eyes and PPV plus IOL eyes. In addition, the encapsuled balanced salt solution changes the refraction little in either schematic eye.
منابع مشابه
The equivalent refractive index of the crystalline lens in childhood
Despite the importance of crystalline lens power in ocular development, schematic refractive index values used to calculate lens power have been validated for children. We measured refractive error and ocular component dimensions in 519 schoolchildren, calculating lens power using phakometrically measured lens radii and three different refractive index profiles: (1) Gullstrand-Emsley schematic ...
متن کاملTreatment-induced shifts of ocular reference axes used for measurement centration.
PURPOSE To determine the shifts of the main corneal reference points in dependence of the chosen centration axis for the treatment. SETTING Federal Institute of Technology Zurich, Institute of Biomedical Engineering, Zurich, Switzerland. METHODS Computer simulations were performed on several variants of the Gullstrand-Emsley schematic eye, which was modified by an off-axis fovea. Refractive...
متن کاملParaxial Schematic Eye Models for 7- and 14-Year-Old Chinese Children.
PURPOSE To develop three-surface paraxial schematic eyes with different ages and sexes based on data for 7- and 14-year-old Chinese children from the Anyang Childhood Eye Study. METHODS Six sets of paraxial schematic eyes, including 7-year-old eyes, 7-year-old male eyes, 7-year-old female eyes, 14-year-old eyes, 14-year-old male eyes, and 14-year-old female eyes, were developed. Both refracti...
متن کاملRefractive changes after descemet stripping endothelial keratoplasty: a simplified mathematical model.
PURPOSE To develop a mathematical model that can predict refractive changes after Descemet stripping endothelial keratoplasty (DSEK). METHODS A mathematical formula based on the Gullstrand eye model was generated to estimate the change in refractive power of the eye after DSEK. This model was applied to four DSEK cases retrospectively, to compare measured and predicted refractive changes afte...
متن کاملCorneal topography and myopia. A cross-sectional study.
PURPOSE Central corneal curvature is known to vary with refractive error, but the relation between corneal topography and ametropia is less clear. The current study was conducted to determine whether a relation exists between corneal asphericity and myopia. Associations between corneal asphericity and each of the components of refraction also were examined. METHODS Corneal asphericity and api...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 50 7 شماره
صفحات -
تاریخ انتشار 2009