Planning strategies for inter-fractional robustness in pancreatic patients treated with scanned carbon therapy
نویسندگان
چکیده
BACKGROUND Managing inter-fractional anatomy changes is a challenging task in radiotherapy of pancreatic tumors, especially in scanned carbon-ion delivery. This treatment planning study aims to focus on clinically feasible solutions, such as the beam angle selection and margin design to increase the robustness against inter-fractional uncertainties. METHODS This study included 10 patients with weekly 3D-CT imaging and physician-approved Clinical Target Volume (CTV). The study was directed to keep the CTV-coverage using six beam angle configurations in combination with different Internal Target Volume (ITV) concepts. These were: geometric-margin (symmetric 3 and 5 mm margin); range-equivalent margins with an isotropic HU replacement; and to evaluate the need of asymmetric margins the water-equivalent range path (WEPL) was determined per patient from the set of CTs. Plan optimization and forward dose calculation in each week-CT were performed with the research treatment planning system TRiP98 and the plan quality evaluated in terms of CTV coverage (V95CTV) and homogeneity dose (HCTV = D5-D95). RESULTS The beam geometry had a substantial impact on the target irradiation over the treatment course, with the single posterior or two beams showing the best average coverage of the CTV. The use of geometric margins for the more robust beam geometries showed acceptable results, with a V95CTV of (99.2 ± 1.2)% for the 5 mm-margin. For the non-robust configurations, due to substantial changes in the radiological depth, the use of this margin results in a V95CTV that might be below 80%, only showing improvement when the range changes are included. CONCLUSIONS Selection of adequate beam configurations and treatment margins in ion-beam therapy of pancreatic tumors is of great importance. For a single posterior beam or two beam configurations, application of geometrical margins compensate for dose degradation induced by inter-fractional anatomy changes for the majority of the analyzed treatment fractions.
منابع مشابه
Worst case optimization for interfractional motion mitigation in carbon ion therapy of pancreatic cancer
INTRODUCTION The efficacy of radiation therapy treatments for pancreatic cancer is compromised by abdominal motion which limits the spatial accuracy for dose delivery - especially for particles. In this work we investigate the potential of worst case optimization for interfractional offline motion mitigation in carbon ion treatments of pancreatic cancer. METHODS We implement a worst case opti...
متن کاملAdequacy of inhale/exhale breathhold CT based ITV margins and image-guided registration for free-breathing pancreas and liver SBRT
PURPOSE To evaluate use of breath-hold CTs and implanted fiducials for definition of the internal target volume (ITV) margin for upper abdominal stereotactic body radiation therapy (SBRT). To study the statistics of inter- and intra-fractional motion information. METHODS AND MATERIALS 11 patients treated with SBRT for locally advanced pancreatic cancer (LAPC) or liver cancer were included in ...
متن کاملCombination Surgical Excision and Fractional Carbon Dioxide Laser for Treatment of Rhinophyma
Rhinophyma is a severe late complication of rosacea, which is characterized by progressive hyperplasia of sebaceous glands and connective tissue involving the lower two-thirds of the nose. It can be an emotionally devastating disorder, and serve as a medium for occult cancers and other health problems. Many surgical treatments have been advocated, as well as dermabrasion and laser therapy. In l...
متن کاملIntra‐ and inter‐fractional liver and lung tumor motions treated with SBRT under active breathing control
PURPOSE To assess intra- and inter-fractional motions of liver and lung tumors using active breathing control (ABC). METHODS AND MATERIALS Nineteen patients with liver cancer and 15 patients with lung cancer treated with stereotactic body radiotherapy (SBRT) were included in this retrospective study. All patients received a series of three CTs at simulation to test breath-hold reproducibility...
متن کاملIon therapy of prostate cancer: daily rectal dose reduction by application of spacer gel
BACKGROUND Ion beam therapy represents a promising approach to treat prostate cancer, mainly due to its high conformity and radiobiological effectiveness. However, the presence of prostate motion, patient positioning and range uncertainties may deteriorate target dose and increase exposure of organs at risk. Spacer gel injected between prostate and rectum may increase the safety of prostate can...
متن کامل