Compensation of geometric distortion effects on intraoperative magnetic resonance imaging for enhanced visualization in image-guided neurosurgery.
نویسندگان
چکیده
OBJECTIVE Preoperative magnetic resonance imaging (MRI), functional MRI, diffusion tensor MRI, magnetic resonance spectroscopy, and positron-emission tomographic scans may be aligned to intraoperative MRI to enhance visualization and navigation during image-guided neurosurgery. However, several effects (both machine- and patient-induced distortions) lead to significant geometric distortion of intraoperative MRI. Therefore, a precise alignment of these image modalities requires correction of the geometric distortion. We propose and evaluate a novel method to compensate for the geometric distortion of intraoperative 0.5-T MRI in image-guided neurosurgery. METHODS In this initial pilot study, 11 neurosurgical procedures were prospectively enrolled. The scheme used to correct the geometric distortion is based on a nonrigid registration algorithm introduced by our group. This registration scheme uses image features to establish correspondence between images. It estimates a smooth geometric distortion compensation field by regularizing the displacements estimated at the correspondences. A patient-specific linear elastic material model is used to achieve the regularization. The geometry of intraoperative images (0.5 T) is changed so that the images match the preoperative MRI scans (3 T). RESULTS We compared the alignment between preoperative and intraoperative imaging using 1) only rigid registration without correction of the geometric distortion, and 2) rigid registration and compensation for the geometric distortion. We evaluated the success of the geometric distortion correction algorithm by measuring the Hausdorff distance between boundaries in the 3-T and 0.5-T MRIs after rigid registration alone and with the addition of geometric distortion correction of the 0.5-T MRI. Overall, the mean magnitude of the geometric distortion measured on the intraoperative images is 10.3 mm with a minimum of 2.91 mm and a maximum of 21.5 mm. The measured accuracy of the geometric distortion compensation algorithm is 1.93 mm. There is a statistically significant difference between the accuracy of the alignment of preoperative and intraoperative images, both with and without the correction of geometric distortion (P < 0.001). CONCLUSION The major contributions of this study are 1) identification of geometric distortion of intraoperative images relative to preoperative images, 2) measurement of the geometric distortion, 3) application of nonrigid registration to compensate for geometric distortion during neurosurgery, 4) measurement of residual distortion after geometric distortion correction, and 5) phantom study to quantify geometric distortion.
منابع مشابه
Geometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes
Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملFabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...
متن کاملRetrospective study comparing model-based deformation correction to intraoperative magnetic resonance imaging for image-guided neurosurgery.
Brain shift during tumor resection compromises the spatial validity of registered preoperative imaging data that is critical to image-guided procedures. One current clinical solution to mitigate the effects is to reimage using intraoperative magnetic resonance (iMR) imaging. Although iMR has demonstrated benefits in accounting for preoperative-to-intraoperative tissue changes, its cost and encu...
متن کاملDesign, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems
Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Neurosurgery
دوره 62 3 Suppl 1 شماره
صفحات -
تاریخ انتشار 2008