Functional intercomparison of intraoperative radiotherapy equipment – Photon Radiosurgery System

نویسندگان

  • Kris S Armoogum
  • John M Parry
  • Salam K Souliman
  • David G Sutton
  • Colin D Mackay
چکیده

BACKGROUND Intraoperative Radiotherapy (IORT) is a method by which a critical radiation dose is delivered to the tumour bed immediately after surgical excision. It is being investigated whether a single high dose of radiation will impart the same clinical benefit as a standard course of external beam therapy. Our centre has four Photon Radiosurgery Systems (PRS) currently used to irradiate breast and neurological sites. MATERIALS AND METHODS The PRS comprises an x-ray generator, control console, quality assurance tools and a mobile gantry. We investigated the dosimetric characteristics of each source and its performance stability over a period of time. We investigated half value layer, output diminution factor, internal radiation monitor (IRM) reproducibility and depth-doses in water. The half value layer was determined in air by the broad beam method, using high purity aluminium attenuators. To quantify beam hardening at clinical depths, solid water attenuators of 5 and 10 mm were placed between the x-ray probe and attenuators. The ion chamber current was monitored over 30 minutes to deduce an output diminution factor. IRM reproducibility was investigated under various exposures. Depth-dose curves in water were obtained at distances up to 35 mm from the probe. RESULTS The mean energies for the beam attenuated by 5 and 10 mm of solid water were derived from ICRU Report 17 and found to be 18 and 24 keV. The average output level over a period of 30 minutes was found to be 99.12%. The average difference between the preset IRM limit and the total IRM count was less than 0.5%. For three x-ray sources, the average difference between the calculated and actual treatment times was found to be 0.62% (n = 30). The beam attenuation in water varied by approximately 1/r(3). CONCLUSION The x-ray sources are stable over time. Most measurements were found to lie within the manufacturer's tolerances and an intercomparison of these checks suggests that the four x-ray sources have similar performance characteristics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Targeted intra-operative radiotherapy (Targit): an innovative method of treatment for early breast cancer.

INTRODUCTION We believe that conservative treatment of early breast cancer may not require radiotherapy that encompasses the whole breast. We present here the clinico-pathological basis for this view, as well as a novel therapeutic approach that allows intra-operative radiotherapy to be safely and accurately delivered to the target tissues in a standard operating theatre. THE RATIONALE: Whole-o...

متن کامل

Evaluation of Dose Calculation Accuracy of Isogray Treatment Planning System in Craniospinal Radiotherapy

Introduction: Craniospinal radiotherapy is a therapeutic technique for central nervous system (CNS) tumors, which requires meticulous attention to technique and dosimetry.Treatment planning system (TPS) is one of the main equipment in radiotherapy; therefore, the evaluation of its accuracy is essential for dose calculation. The present study evaluates the validity of Isogray TPS in craniospinal...

متن کامل

Intraoperative radiation therapy with the photon radiosurgery system in locally advanced and recurrent rectal cancer: retrospective review of the Cleveland clinic experience

BACKGROUND Patients with locally advanced or recurrent rectal cancer often require multimodality treatment. Intraoperative radiation therapy (IORT) is a focal approach which aims to improve local control. METHODS We retrospectively reviewed 42 patients treated with IORT following definitive resection of a locally advanced or recurrent rectal cancer from 2000-2009. All patients were treated wi...

متن کامل

A dosimetric intercomparison of kilovoltage X-rays, megavoltage photons and electrons in the Republic of Ireland.

BACKGROUND AND PURPOSE A comprehensive dosimetry intercomparison has been carried out involving all the radiotherapy centres, all external beam modalities and every radiotherapy treatment unit in the Republic of Ireland. MATERIALS AND METHODS Reference point measurements were made for all megavoltage photon beams. Doses were also investigated in planned three-field distributions. One of these...

متن کامل

Small photon field dosimetry using EBT2 Gafchromic film and Monte Carlo simulation

Background: Small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (IMRT) and stereotactic radiosurgery (SRS) treatments. Accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. Hence the EBT2 (external beam therapy) Gafchromic film was used for dosimetry of sm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation Oncology (London, England)

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2007