Evaluation of speed, repeatability, and reproducibility of digital radiography with manual versus computer-assisted cephalometric analyses.

نویسندگان

  • Tancan Uysal
  • Asli Baysal
  • Ahmet Yagci
چکیده

The aims of this study were to evaluate intra-examiner repeatability and inter-examiner reproducibility of landmarks using two cephalometric analysing techniques, manual and computerized, and to compare these for speed. One hundred lateral cephalometric radiographs were randomly selected and 11 angular and six linear parameters were traced and measured by two examiners using the manual method and Dolphin Image Software 9.0 on each radiograph. A Student's t-test for paired and independent samples was used to compare the mean values of intra- and inter-examiner differences. Intraclass correlation coefficients (ICC) were calculated to determine intra- and inter-examiner correlation (r value). Both operators were generally consistent in the repeated measurements; however, for one examiner, the differences for Na is perpendicular to A (P < 0.001), Na is perpendicular Pog, and U1-NA (P < 0.01) distance measurements were found to be statistically significant. Intra-examiner repeatability of landmarks both with the manual and Dolphin techniques showed high correlation coefficients. While inter-examiner reproducibility of landmarks was unacceptable, measurement errors with the manual technique were generally comparable with the Dolphin technique. The mean tracing times of the two operators for a single tracing was 2 minutes 41 seconds for Dolphin and 6 minutes 51 seconds for manual tracings. Computer-assisted cephalometric analysis does not increase intra- and inter-examiner reliability but can result in time saving.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The assessment of accuracy and reproducibility of cephalometric analyses using Computer- Assisted Simulation System for Orthognathic Surgery (CASSOS) software

Cephalometric analyses using computer software have more advantages than manual analyses. However, the software should be evaluated for the accuracy and reproducibility before it can be used. The aims of the present study were: 1) to compare the differences in accuracy and precision between utilizing scanned images and soft copy images with the software 2) to assess the reproducibility of softw...

متن کامل

مقایسه تفاوت لندمارک های آناتومیک دو تکنیک رادیوگرافی لترال سفالومتری دیجیتال و معمولی به روش ترسیم دستی در جمجمه های انسانی

Background and purpose: Digital radiography has led to many improvements in radiology. Despite many advantages there are different ideas in determining anatomical landmarks which results in some errors in cephalometric analyses. The aim of this study was to determine the degree of identification differences of anatomical landmarks by conventional and digital lateral cephalometric techniques usi...

متن کامل

Validity and reproducibility of cephalometric measurements obtained from digital photographs of analogue headfilms.

UNLABELLED The emerging market of digital cephalographs and computerized cephalometry is overwhelming the need to examine the advantages and drawbacks of manual cephalometry, meanwhile, small offices continue to benefit from the economic efficacy and ease of use of analogue cephalograms. The use of modern cephalometric software requires import of digital cephalograms or digital capture of analo...

متن کامل

Determining the Correlation amount of Ordinary and Digital Cephalometric lateral Radiography in angular Measurements by using Dolphin Imaging 10 software

Cephalometric lateral radiography is an important paraclinical tool in diagnosing and treatment design of skeletaldental malocclusions. Objective of this study is to determine accuracy amount of measurements of cephalometry in two types of digital and ordinary graphy to specify the more beneficial method having more accuracy. In this descriptive-analytical study samples include digital and ordi...

متن کامل

Accuracy Evaluation of The Depth of Six Kinds of Sperm Counting Chambers for both Manual and Computer-Aided Semen Analyses

Background Although the depth of the counting chamber is an important factor influencing sperm counting, no research has yet been reported on the measurement and comparison of the depth of the chamber. We measured the exact depths of six kinds of sperm counting chambers and evaluated their accuracy. MaterialsAndMethods In this prospective study, the depths of six kinds of sperm counting chamber...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of orthodontics

دوره 31 5  شماره 

صفحات  -

تاریخ انتشار 2009