Ventilation with Lower Tidal Volumes as Compared with Traditional Tidal Volumes for Acute Lung Injury and the Acute Respiratory Distress Syndrome

نویسنده

  • Michael A. Matthay
چکیده

A BSTRACT Background Traditional approaches to mechanical ventilation use tidal volumes of 10 to 15 ml per kilogram of body weight and may cause stretch-induced lung injury in patients with acute lung injury and the acute respiratory distress syndrome. We therefore conducted a trial to determine whether ventilation with lower tidal volumes would improve the clinical outcomes in these patients. Methods Patients with acute lung injury and the acute respiratory distress syndrome were enrolled in a multicenter, randomized trial. The trial compared traditional ventilation treatment, which involved an initial tidal volume of 12 ml per kilogram of predicted body weight and an airway pressure measured after a 0.5-second pause at the end of inspiration (plateau pressure) of 50 cm of water or less, with ventilation with a lower tidal volume, which involved an initial tidal volume of 6 ml per kilogram of predicted body weight and a plateau pressure of 30 cm of water or less. The first primary outcome was death before a patient was discharged home and was breathing without assistance. The second primary outcome was the number of days without ventilator use from day 1 to day 28. Results The trial was stopped after the enrollment of 861 patients because mortality was lower in the group treated with lower tidal volumes than in the group treated with traditional tidal volumes (31.0 percent vs. 39.8 percent, P=0.007), and the number of days without ventilator use during the first 28 days after randomization was greater in this group (mean [±SD], 12±11 vs. 10±11; P=0.007). The mean tidal volumes on days 1 to 3 were 6.2±0.8 and 11.8±0.8 ml per kilogram of predicted body weight (P<0.001), respectively, and the mean plateau pressures were 25±6 and 33±8 cm of water (P<0.001), respectively. Conclusions In patients with acute lung injury and the acute respiratory distress syndrome, mechanical ventilation with a lower tidal volume than is traditionally used results in decreased mortality and increases the number of days without ventilator use. (N Engl J Med 2000;342:1301-8.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury.

Traditional approaches to mechanical ventilation use tidal volumes of 10 to 15 ml per kilogram of body weight. These volumes are larger than those in normal subjects at rest (range, 7 to 8 ml per kilogram), but they are frequently necessary to achieve normal values for the partial pressure of arterial carbon dioxide and pH. Since atelectasis and edema reduce aerated lung volumes in patients wit...

متن کامل

Ventilation with Lower Tidal Volumes as Compared with Traditional Tidal Volumes for Acute Lung Injury and the Acute Respiratory Distress Syndrome

Background. Traditional approaches to mechanical ventilation use tidal volumes of 10 to 15 ml per kilogram of body weight and may cause stretch-induced lung injury in patients with acute lung injury and the acute respiratory distress syndrome. We therefore conducted a trial to determine whether ventilation with lower tidal volumes would improve the clinical outcomes in these patients. Methods. ...

متن کامل

Ventilator induced lung injury and infection in the critically ill.

Background: Traditional approaches to mechanical ventilation use tidal volumes of 10–15 ml/kg body weight and may cause stretch-induced lung injury in patients with acute lung injury and the acute respiratory distress syndrome. We therefore conducted a trial to determine whether ventilation with lower tidal volumes would improve the clinical outcomes in these patients. Methods: Patients with ac...

متن کامل

Very Low Tidal Volume Ventilation with Associated Hypercapnia - Effects on Lung Injury in a Model for Acute Respiratory Distress Syndrome

BACKGROUND Ventilation using low tidal volumes with permission of hypercapnia is recommended to protect the lung in acute respiratory distress syndrome. However, the most lung protective tidal volume in association with hypercapnia is unknown. The aim of this study was to assess the effects of different tidal volumes with associated hypercapnia on lung injury and gas exchange in a model for acu...

متن کامل

Bronchoalveolar Activation of Coagulation and Inhibition of Fibrinolysis during Ventilator-Associated Lung Injury

Background and Objective. Bronchoalveolar coagulopathy is a characteristic feature of pulmonary inflammation. We compared bronchoalveolar and systemic levels of coagulation in patients who did and patients who did not develop ventilator-associated lung injury (VALI). Methods. Secondary analysis of a randomized controlled trial evaluating the effect of lower tidal volumes versus conventional tid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000