Additional coronary sinus shocking lead as rescue therapy after multiple internal and external defibrillation failures

نویسندگان

  • Samuel Chauveau
  • Arnaud Dulac
  • Laurent Sebbag
  • Elodie Morel
  • Philippe Chevalier
چکیده

High defibrillation threshold (DFT) and defibrillation failure can lead to intractable ventricular arrhythmias. Additional coronary sinus coil is an effective strategy to achieve marked reduction in DFT. However, physicians should retain this might prevent future coronary sinus lead placement in case the patient would develop complete left bundle branch block.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transvenous biventricular defibrillation halves energy requirements in patients.

BACKGROUND Defibrillation thresholds (DFT) with standard implantable cardioverter-defibrillator leads in the right ventricle (RV) may be determined by weak shock field intensity in the myocardium of the left ventricle (LV). Adding a shocking electrode in a coronary vein on the middle of the LV free wall, thereby establishing biventricular defibrillation, substantially reduced defibrillation req...

متن کامل

Implantation of additional defibrillation lead into the coronary sinus: an effective method of decreasing defibrillation threshold.

We report a case of successful implantation of an additional defibrillation lead into the coronary sinus due to high defibrillation threshold (DFT) in a seriously ill patient with a history of extensive myocardial infarction referred for implantable cardioverter- defibrillator implantation after an episode of unstable ventricular tachycardia. All previous attempts to reduce DFT, including subcu...

متن کامل

Differential effects of defibrillation on systemic and cardiac sympathetic activity.

OBJECTIVE To assess the effect of defibrillation shocks on cardiac and circulating catecholamines. DESIGN Prospective examination of myocardial catecholamine balance during dc shock by simultaneous determination of arterial and coronary sinus plasma concentrations. Internal countershocks (10-34 J) were applied in 30 patients after initiation of ventricular fibrillation for a routine implantab...

متن کامل

DiVerential eVects of defibrillation on systemic and cardiac sympathetic activity

Objective—To assess the eVect of defibrillation shocks on cardiac and circulating catecholamines. Design—Prospective examination of myocardial catecholamine balance during dc shock by simultaneous determination of arterial and coronary sinus plasma concentrations. Internal countershocks (10– 34 J) were applied in 30 patients after initiation of ventricular fibrillation for a routine implantable...

متن کامل

A Prospective, Randomized Study

Background Recent development of a prototype singlelead unipolar transvenous defibrillator offers the possibility of device implantation with the ease of a permanent pacemaker. Lowering defibrillation energy requirements would allow for a further reduction in defibrillator generator size and enhance the feasibility of pacemaker-like placement. However, if achieving a lower defibrillation energy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017