Cardiac Imaging with Chemical Shift Based Water-Fat Separation at 3T
نویسندگان
چکیده
Introduction Chemical shift based water-fat separation techniques have been demonstrated for 1.5T cardiac imaging of several pathologies, including fatty infiltration of chronic infarction; arrhythmogenic right ventricular cardiomyopathy (ARVC); fatty tumors; and conditions such as myocarditis and pericarditis [1-4]. Higher field strengths (3T) are now often used in cardiac MRI due to improved image contrast, SNR, and tagging efficiency [5]. However, chemical shift-based separation methods at 3T can be challenging due to the short required echo spacing. Here we demonstrate the use of a chemical-shift based water-fat decomposition method (IDEAL) [6,7] for 3T cardiac imaging. Methods A multi-echo gradient echo sequence with 2 fractional (partial-kx) echoes acquired with positive (fly-back) readouts was implemented at 3T (Discovery MR750, GE Healthcare, Waukesha, WI). An 8-channel cardiac coil or a 32-channel torso coil with the most superior 20 elements activated (NeoCoil, Pewaukee, WI) was used. Two interleaved echo trains with 2 echoes per TR were acquired for each k-space line (Fig. 1), providing an effective echo spacing within the optimal range that maximizes SNR performance. Normally, it is extremely challenging to achieve such echo spacing at 3T while maintaining high spatial resolution. Acquisition parameters included: TR/TE1/ΔTE/BW = 6.3/1.7-1.9/0.8-0.9/±125kHz; FOV/Matrix/Slice Thickness = 35cm/256x192/6-8mm; 24 views per segment; and imaging in every second cardiac cycle, with 17 cardiac cycles per slice. For delayed enhancement imaging, inversion recovery (IR) was used, with TI=250-300ms adjusted as needed to null normal myocardium. The technique was used in a variety of clinical imaging situations, and informed consent was obtained in all patients. Water-fat decomposition was performed with an investigational reconstruction software package, with an advanced region-growing field estimation method [8].
منابع مشابه
Compressed sensing for chemical shift-based water-fat separation.
Multi echo chemical shift-based water-fat separation methods allow for uniform fat suppression in the presence of main field inhomogeneities. However, these methods require additional scan time for chemical shift encoding. This work presents a method for water-fat separation from undersampled data (CS-WF), which combines compressed sensing and chemical shift-based water-fat separation. Undersam...
متن کاملFeasibility of T2* Estimation with Chemical Shift-Based Water-Fat Separated Cardiac Imaging
Introduction T2* mapping has been investigated in cardiac MRI for imaging the myocardial BOLD effect [1] and in iron overload assessment [2]. Advanced T2* estimation techniques in the context of chemical shift-based water-fat decomposition have recently been developed for iron detection in organs such as the liver, while simultaneously estimating fat content [3]. Separately, chemical shiftbased...
متن کاملCS-Dixon: Compressed Sensing for Water-Fat Dixon Reconstruction
Introduction: Water-fat separation is of interest in several MRI applications including fat suppression and fat quantification. Chemical shift imaging allows robust water-fat separation [1, 2], however the acquisition of multiple images results in prolonged scan time. Accelerated water-fat separation using compressed sensing (CS) was partly addressed in [3] by considering the separation as a sp...
متن کاملFast gradient-echo chemical-shift imaging.
A fast chemical-shift imaging using the gradient-echo technique is proposed for the separation of the water and fat in human in vivo imaging. This technique also incorporates magnetic field inhomogeneity correction in the fast chemical-shift imaging. Experimental results of the proposed imaging technique demonstrate that the method would be useful for quick in vivo water-fat separation imaging ...
متن کاملMultiecho dixon fat and water separation method for detecting fibrofatty infiltration in the myocardium.
Conventional approaches for fat and water discrimination based on chemical-shift fat suppression have reduced ability to characterize fatty infiltration due to poor contrast of microscopic fat. The multiecho Dixon approach to water and fat separation has advantages over chemical-shift fat suppression: 1) water and fat images can be acquired in a single breathhold, avoiding misregistration; 2) f...