Comparison of the latex agglutination test with the hemagglutination inhibition test, enzyme-linked immunosorbent assay, and neutralization test for detection of antibodies to rubella virus.
نویسندگان
چکیده
The ability of a rapid, latex agglutination test to diagnose rubella infection and to measure immune status was evaluated by comparison with the hemagglutination-inhibition (HAI) test, enzyme-linked immunosorbent assay (ELISA), and the neutralization (NT) test. The latex agglutination test accurately detected serological conversions in 74 pairs of sera representing 21 natural infections and 53 immunizations. The antibody levels of 276 sera from the general population were determined by latex agglutination, HAI, and ELISA. The correlation coefficients between the titers obtained by HAI and latex agglutination and by ELISA and latex agglutination were statistically significant. Results on 12 sera did not agree when measured by the three tests. These sera were included among the 196 specimens tested by NT. The correlation coefficient between NT and latex agglutination titers was statistically significant. There was one serum positive by latex agglutination but negative by NT, and five sera were negative by latex agglutination but had titers of 4 to 8 in the NT. The relative sensitivity of detecting antibody was greater by latex agglutination than by HAI. An additional 49 sera containing residual nonspecific hemagglutinin inhibitors were evaluated by latex agglutination and NT. The untreated sera showed no false positive reactions, and 36 of 39 NT positive sera were positive in the latex agglutination test.
منابع مشابه
Comparison of enzyme-linked immunosorbent assay, hemagglutination inhibition, and passive latex agglutination for determination of rubella immune status.
Hemagglutination inhibition, enzyme-linked immunosorbent assay (ELISA), and passive latex agglutination were used to test 495 human serum samples for determination of rubella immunity. Overall agreements for immune status were as follows: hemagglutination inhibition versus ELISA, 94.7% (469 of 495); hemagglutination inhibition versus passive latex agglutination (1:10 dilution), 99.2% (491 of 49...
متن کاملRapid latex agglutination test for rubella antibody.
The latex agglutination card test (Rubascan) for the detection of rubella antibody was compared with the standard hemagglutination inhibition and enzyme-linked immunosorbent assay tests. There was complete agreement with sera which had hemagglutination inhibition titers of >/=16. Sera with low levels of antibody which were positive in the enzyme-linked immunosorbent assay, however, gave negativ...
متن کاملStandardization of an Enzyme-Linked Immunosorbent Assay for Detection of Infectious Bronchitis Virus Antibody.
An indirect enzyme–linked immunosorbent assay (ELISA) was developed for screening of antibody to avian infectious bronchitis virus (IBV). Antigen was prepared from whole-purified IBV Massachusetts serotype (BR 801 strain). Optimum dilution with minimum background for antigen concentration, rabbit anti-chicken conjugate and sera in developed ELISA was determined 0.1μg/ml, 1:3000 and 1:100, respe...
متن کاملEvaluation of a Latex Agglutination Test for Detection of Antibodies to Rubella Virus in Selected Sera
A new latex agglutination test for rubella virus was used to test sera with a hemagglutination inhibition titer of -8 (97 specimens) or >256 (158 specimens). Maximum latex agglutination test sensitivity was achieved when low-titer sera were tested undiluted and high-titer sera were diluted (1:10). A modification of the protocol of the manufacturer resulted in a latex agglutination-hemagglutinat...
متن کاملAvidin-biotin latex agglutination assay for detection of antibodies to viral antigens.
A new method for attaching antigens to latex by an avidin-biotin technique is described. The procedure permits control of the amount of antigen attached to the latex and eliminates the need for highly purified antigens and destructive bridging chemicals. The avidin-biotin latex agglutination assay is a simple, rapid test well suited to detection of viral antibody. The sensitivity and specificit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 16 4 شماره
صفحات -
تاریخ انتشار 1982