Right ventricular dysfunction following continuous flow left ventriccular assist device placement in 51 patients: predicators and outcomes

نویسندگان

  • Siyamek Neragi-Miandoab
  • Daniel Goldstein
  • Ricardo Bello
  • Robert Michler
  • David D’Alessandro
چکیده

BACKGROUND Right ventricular (RV) dysfunction following implantation of a left ventricular assist device (LVAD) is a serious condition and is associated with increased mortality. METHODS The aim of the study is to investigate the significance of pre-existing RV dysfunction, tricuspid valve (TV) insufficiency, and the severity of septal deviation following LVAD implantation on RV dysfunction, as well as the outcome and short-term complications in 51 patients from June 2006 to August 2010. Student t test was used to compare the data and estimate the p value. RESULTS Mean age was 55.1 ± 13, with a male to female ratio of 3.25. The 30-day mortality was 13.7% (7/51 patients), and the overall mortality was 23.5% (12/51 patients). Meanwhile, 21 patients (21/51; 41.2%) have undergone orthotopic heart transplantation. The mean time of support was 314.5±235 days with a median of 240 days at the time of closing this study. Echocardiographic evaluation of RV function pre- and post-implantation of an LVAD demonstrated septal deviation towards the left ventricle in immediate postoperative phase, which correlated with acute RV dysfunction (p = 0.002). Preoperative RV dysfunction was a significant predictor of postoperative right heart dysfunction following implantation of an LVAD (p = 0.001). CONCLUSION Preoperative RV dysfunction is a predictor of RV failure in LVAD patients. The adjustment of septal deviation through gradual increase of the LVAD flow can prevent the acute RV dysfunction following LVAD placement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.

BACKGROUND Right heart dysfunction confers significant morbidity and mortality after left ventricular assist device implantation and historically occurs in as many as a third of patients. It is unknown whether newer axial flow pumps have a different impact on postimplant right heart dysfunction. We compared the incidence of right heart dysfunction after implantation of the pulsatile HeartMate I...

متن کامل

Apical pseudoaneurysm following continuous flow left ventricular assist device placement.

The HeartMate II continuous flow left ventricular assist device (LVAD) (Thoratec Inc) provides circulatory support for patients with medically refractory systolic heart failure as both a bridge to transplantation and destination therapy. Although left ventricular apical pseudoaneurysm has rarely been reported with first-generation pulsatile flow LVADs, this has not been previously reported with...

متن کامل

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes.

OBJECTIVE The aim of this study was to evaluate the incidence, risk factors, and effect on outcomes of right ventricular failure in a large population of patients implanted with continuous-flow left ventricular assist devices. METHODS Patients (n = 484) enrolled in the HeartMate II left ventricular assist device (Thoratec, Pleasanton, Calif) bridge-to-transplantation clinical trial were exami...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012