Handling of Polyvinylsiloxane Versus Polyether for Implant Impressions.
نویسندگان
چکیده
PURPOSE This study compared polyvinylsiloxane with polyether in handling dental impressions. MATERIALS AND METHODS Each participant (N = 39) made four impressions, each a combination of pickup and reseating techniques with polyether or polyvinylsiloxane, of one implant cast representing a specific clinical situation (tooth gaps, limited residual dentition, or edentulous jaw). Handling of impressions was subsequently rated by using a 12-item questionnaire with 100-mm visual analog scales. RESULTS While mean satisfaction scores were higher for polyvinylsiloxane than for polyether (69.5/63.0, P < .001), differences among subgroups were statistically significant only for pickup technique, limited residual dentition, and edentulous jaw. CONCLUSION Implant impressions made with polyvinylsiloxane using a pickup technique seem to be the best option for most clinical situations.
منابع مشابه
Evaluation of accuracy of complete-arch multiple-unit abutment-level dental implant impressions using different impression and splinting materials.
PURPOSE This in vitro study evaluated the accuracy of multiple-unit dental implant casts obtained from splinted or nonsplinted direct impression techniques using various splinting materials by comparing the casts to the reference models. The effect of two different impression materials on the accuracy of the implant casts was also evaluated for abutment-level impressions. MATERIALS AND METHOD...
متن کاملتعیین دقت ثبت ایمپلنت و جزئیات سطحی با استفاده از پلیاتر و پلیوینیل سایلوکسان با روش تری بسته
Background and Aims: Making accurate impressions of prepared teeth when they are adjacent to dental implants is of great importance. In these situations, disregarding the selection of appropriate impression material and technique, not only can affect accuracy of transferring of the 3-dimentional spatial status of implant, but also can jeopardize the accurate recording of tooth. In the present...
متن کاملEffect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study.
BACKGROUND With regard to implant-supported prostheses, to date no technique has been proven to guarantee a completely passive fit of prosthetic frameworks. Several clinical variables may affect the precision of impressions, particularly in the presence of implants. PURPOSE To compare the accuracy of implant impressions made with different materials, lengths of impression coping connections, ...
متن کاملIn vivo Study of the Accuracy of Dual-arch Impressions.
BACKGROUND This study evaluated in vivo the accuracy of metal (Smart®) and plastic (Triple Tray®) dual-arch trays used with vinyl polysiloxane (Flexitime®), in the putty/wash viscosity, as well as polyether (Impregum Soft®) in the regular viscosity. MATERIALS AND METHODS In one patient, an implant-level transfer was screwed on an implant in the mandibular right first molar, serving as a patte...
متن کاملEffect of Conventional and Experimental Gingival Retraction Solutions on the Tensile Strength and Inhibition of Polymerization of Four Types of Impression Materials
In the present study, two types of tests (tensile strength test and polymerization inhibition test) were performed to evaluate the physical and chemical properties of four impression materials [a polysulfide (Permlastic), a polyether (Impregum), a condensation silicone (Xantopren) and a polyvinylsiloxane (Aquasil)] when polymerized in contact with of one conventional (Hemostop) and two experime...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of prosthodontics
دوره 29 4 شماره
صفحات -
تاریخ انتشار 2016