Evaluation of clinical dry weight assessment in haemodialysis patients using bioimpedance spectroscopy: a cross-sectional study.

نویسندگان

  • Jens Passauer
  • Helga Petrov
  • Andreas Schleser
  • Joachim Leicht
  • Klaus Pucalka
چکیده

BACKGROUND Dry weight assessment (DWA) is essential to efficient therapy of haemodialysis (HD) patients. However, so far objective methods for DWA have not been applicable to daily routine. Thus, exact fluid management in HD remains difficult and is often based on clinical criteria. The aims of this study were (1) to objectively define pre- and post-dialytic ranges of extracellular volume in a large cohort of HD patients (in whom DWA had been defined according to clinical criteria), (2) to compare the hydration status between diabetic and non-diabetic patients, and (3) to assess a patient subgroup that might benefit from correction of target weight. METHODS We measured fluid overload (FO) prior to a mid-week HD session in 370 randomly selected HD patients (50% with diabetes) from five dialysis centres. A new bioimpedance spectroscopy (BIS) device that implies a validated body composition model was applied. This tool allows correct quantification of extracellular FO or - deficiency in comparison to a healthy reference population (normal range -1.1 to 1.1 L according to the 10th and 90th percentile of measurements). In addition, weight and blood pressure were recorded before and after treatment. RESULTS Pre-dialytic FO ranged from -0.5 to 4 L and post-dialytic FO from -2.5 to 2 L (10th and 90th percentile of measurements), indicating that on average the hydration status of healthy subjects is considered as the optimal target weight in HD patients. Comparison of FO between diabetic and non-diabetic patients revealed no difference. Based on the consideration that an FO < -1.1 L before and >1.1 L after HD indicates inadequate DWA, we identified 98 (26%) patients who might benefit from correction of target body weight. CONCLUSION BIS is an interesting, objective method to support clinical DWA. Further studies should be performed to investigate beneficial clinical effects of this approach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical praxis for assessment of dry weight in Sweden and Denmark: A mixed-methods study.

Overhydration is an independent predictor of mortality in hemodialysis (HD) patients. More than 30% of HD patients are overhydrated, motivating the development of new methods for assessing hydration status. This study surveyed clinical praxis and local guidelines for dry weight (DW) assessment in Swedish and Danish HD units, and examined if differences in routines and utilization of bioimpedanc...

متن کامل

Intradialytic hypertension during chronic haemodialysis and subclinical fluid overload assessed by bioimpedance spectroscopy

BACKGROUND Intradialytic hypertension (IDH) increases morbidity and mortality. The prevalence in South Africa is unknown. The pathogenesis is unclear, but it has been suggested that IDH may be due to subclinical fluid overload. The objective of this study was to determine the prevalence of IDH and to evaluate its association with fluid overload using bioimpedance spectroscopy (BIS). METHODS A...

متن کامل

Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation

BACKGROUND Maintenance of the optimal fluid status in hemodialysis patients is still a challenging task in daily clinical practice. A bioelectric impedance technique has been applied for evaluation of hydration status in the dialysis population in recent years, but serial observations of its role in clinical dry weight determination are lacking. In this study, serial follow-up data of a body co...

متن کامل

Importance of whole-body bioimpedance spectroscopy for the management of fluid balance.

INTRODUCTION Achieving normohydration remains a non-trivial issue in haemodialysis therapy. Preventing the deleterious effects of fluid overload and dehydration is difficult to achieve. Objective and clinically applicable methods for the determination of a target representing normohydration are needed. METHODS Whole-body bioimpedance spectroscopy (50 frequencies, 5-1,000 kHz) in combination w...

متن کامل

The role of natriuretic peptides in volume assessment and mortality prediction in Haemodialysis patients.

BACKGROUND Maintaining optimal fluid balance is essential in haemodialysis (HD) patients but clinical evaluation remains problematic. Other technologies such as bioimpedance are emerging as valuable adjuncts. This study was undertaken to explore the potential utility of the natriuretic peptides - atrial natriuretic peptide (ANP) and B-type natriuretic peptide (BNP) in the assessment of fluid st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 2010