Muramic acid is not generally present in the human spleen as determined by gas chromatography-tandem mass spectrometry.

نویسندگان

  • Michael P Kozar
  • Jon D Laman
  • Alvin Fox
چکیده

It has been hypothesized that bacterial debris may accumulate in tissues of the reticuloendothelial system (RES) serving as an inflammatory stimulus for human disease. In support of this hypothesis, muramic acid (Mur), a component of bacterial peptidoglycan (PG), has previously been reported to be present in culture-negative human spleen. High-performance liquid chromatography (HPLC) was employed in these analyses, and a peak was detected at the retention time of Mur. However, HPLC is best used as a screening technique, and it is vital that these tentative observations be reexamined by the state-of-the-art approach (gas chromatography-tandem mass spectrometry [GC-MS(2)]). Indeed, in the present work using GC-MS(2), Mur was not detected in six out of seven human spleens previously examined by HPLC. However, Mur was categorically detected at minute concentrations, 50 ppb, in one spleen. In conclusion, since Mur is not generally found in culture-negative human spleen, in future studies, these tissues can serve as negative controls. The study of Mur levels in inflammation (e.g., reactive arthritis) could prove important in testing the hypothesis that bacterial debris persisting in tissues could serve as a depot inciting diseases of unknown etiology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Failure To detect muramic acid in normal rat tissues but detection in cerebrospinal fluids from patients with Pneumococcal meningitis.

Muramic acid serves as a marker for the presence of bacterial cell wall debris in mammalian tissues. There have been a number of controversial and sometimes conflicting results on assessing the levels of muramic acid in health and disease. The present report is the first to use the state-of-the art technique, gas chromatography-tandem mass spectrometry, to identify and quantify the levels of mu...

متن کامل

Analysis of a stable halogenated derivative of muramic acid by gas chromatography-negative ion chemical ionization tandem mass spectrometry.

Muramic acid (Mur) is present in the cell wall of Eubacteria and serves as a chemical marker for the trace detection of bacteria and bacterial cell wall debris in complex matrices. There have been numerous studies using a variety of derivatives of Mur, particularly in combination with gas chromatography-tandem mass spectrometry (GC-MS-MS) where the detection limit has been steadily lowered. A s...

متن کامل

Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Infection and immunity

دوره 70 2  شماره 

صفحات  -

تاریخ انتشار 2002