Comparison of outcomes in patients undergoing defibrillation threshold testing at the time of implantable cardioverter-defibrillator implantation versus no defibrillation threshold testing.

نویسندگان

  • Burr Hall
  • Vinodh Jeevanantham
  • Ethan Levine
  • James Daubert
  • Scott McNitt
  • Freburr Hall
  • Fred Morady And Frank Pelosiburr Hall
  • Fred Morady And Frank Pelosid Morady
  • Frank Pelosi
چکیده

BACKGROUND Inability to perform defibrillation threshold (DFT) testing during implantable cardioverter defibrillator (ICD) implantation due to co-morbidities may influence long-term survival. METHODS Retrospective review at The University of Michigan (1999-2004) identified 55 patients undergoing ICD implantation without DFT testing ("No-DFT group"). A randomly selected sample of patients (n = 57) undergoing standard DFT testing ("DFT group") was compared in terms of appropriate shocks, clinical shock efficacy and all-cause mortality. RESULTS DFT testing was withheld due to hypotension, atrial fibrillation with inability to exclude left atrial thrombus, left ventricular thrombus, CHF and/or ischemia. The No-DFT group had a similar appropriate shock rate, but lower total survival (69.1% vs. 91.2%, p = 0.004) than the DFT group. The No-DFT group had a higher incidence of ventricular fibrillation (VF) episodes (9.1% vs. 3.1%, p = 0.037), and deaths attributable to VF (3 of 17 deaths vs. 0 of 5 deaths) compared to the DFT group. Multivariate analysis found a trend toward increased risk of death in the No-DFT group (HR 3.18, 95% CI 0.82-12.41, p = 0.095) after adjusting for baseline differences in gender distribution, NYHA class and prior CABG. CONCLUSIONS In summary, overall mortality was higher in the No-DFT group. More deaths attributable to VF occurred in the No-DFT group. Thus, DFT testing should therefore remain the standard of care. Nevertheless, ICD therapy should not be withheld in patients who meet appropriate implant criteria simply on the basis of clinical scenarios that preclude routine DFT testing. (Cardiol J 2007; 14: 463-469).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations).

BACKGROUND Implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators have relied on multiple ventricular fibrillation (VF) induction/defibrillation tests at implantation to ensure that the device can reliably sense, detect, and convert VF. The ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduc...

متن کامل

Systematic Review of Defibrillation Threshold Testing at De Novo Implantation.

BACKGROUND Recent results from the largest multicenter randomized trial (Shockless IMPLant Evaluation [SIMPLE]) on defibrillation threshold (DFT) testing suggest that while shock testing seems safe, it does not reduce the risk of failed shocks or prolong survival. A contemporary systematic review of DFT versus no-DFT testing at the time of implantable cardioverter-defibrillator implantation was...

متن کامل

Efficacy and Temporal Stability of Reduced Safety Margins for Ventricular Defibrillation

Background—Traditionally, a safety margin of at least 10 J between the maximum output of the pulse generator and the energy needed for ventricular defibrillation has been used because lower safety margins were associated with unacceptably high rates of failed defibrillation and sudden cardiac death. The Low Energy Safety Study (LESS) was a prospective, randomized assessment of the safety margin...

متن کامل

Defibrillation threshold testing does not predict clinical outcomes during long-term follow-up: a meta-analysis.

BACKGROUND Defibrillation threshold (DFT) testing at the time of implantable cardioverter defibrillator (ICD) implantation is widely used in clinical practice, but reliable data supporting its routine use are lacking. We undertook a meta-analysis to evaluate the efficacy of DFT testing compared to no DFT testing at the time of ICD implantation. METHODS We searched the MEDLINE and EMBASE datab...

متن کامل

Defibrillation threshold testing fails to show clinical benefit during long-term follow-up of patients undergoing cardiac resynchronization therapy defibrillator implantation.

BACKGROUND The utility of defibrillation threshold testing in patients undergoing implantable cardioverter-defibrillator (ICD) implantation is controversial. Higher defibrillation thresholds have been noted in patients undergoing implantation of cardiac resynchronization therapy defibrillators (CRT-D). Since the risks and potential benefits of testing may be higher in this population, we sought...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiology journal

دوره 14 5  شماره 

صفحات  -

تاریخ انتشار 2007