Performance characteristics of the immunoglobulin G-capture BED-enzyme immunoassay, an assay to detect recent human immunodeficiency virus type 1 seroconversion.

نویسندگان

  • Trudy Dobbs
  • Susan Kennedy
  • Chou-Pong Pau
  • J Steven McDougal
  • Bharat S Parekh
چکیده

Recently, we developed an immunoglobulin G (IgG)-capture BED-enzyme immunoassay (BED-CEIA) to identify recent human immunodeficiency virus (HIV) type 1 (HIV-1) seroconversion for use in incidence estimates. We have established an algorithm for its use; developed quality control reagents to monitor the assay; and evaluated its performance for interrun, intrarun, and operator variability. Analysis of 144 individual plates, which involved multiple plate lots and several operators over more than a year, indicated that the coefficients of variation (CVs) were between 10 and 15% for raw optical density (OD) values in the dynamic range between 0.5 and 2.0 OD units; the CVs decreased to 5 to 10% when the OD was normalized (OD-n; OD-n = specimen OD/calibrator OD). The intrarun CVs were generally in the range of 5 to 10% for specimens with ODs <0.5 and less than 5% for specimens with ODs >0.5. The level of concordance between multiple plate lots (n = 6) and multiple operators (n = 7) was quite high (R(2) > 0.9). Comparison of the results of the initial and the confirmatory tests with specimens with OD-n values </=1.5 demonstrated a high degree of correlation (R(2) = 0.92); 566 (92%) of 615 of specimens tested in the two modes retained the same classification (recent or long-term infection). The values for those specimens with changed classifications (n = 49) were close to the cutoff (OD-n = 1.0), as expected. The twofold difference in the HIV IgG contents between the controls and the calibrator reagents was exploited to monitor individual plate runs by using a control plot, which was incorporated into the spreadsheet for data entry and run monitoring. This information provides baseline data for the successful transfer of BED-CEIA to other laboratories and the use of BED-CEIA for the detection of recent HIV seroconversion and the calculation of incidence estimates worldwide.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early detection of antibody to human immunodeficiency virus type 1 by using an antigen conjugate immunoassay correlates with the presence of immunoglobulin M antibody.

Sequential plasma samples obtained from 16 individuals who seroconverted were tested for the presence of antibody to human immunodeficiency virus type 1 (HIV-1) by an antigen conjugate enzyme immunoassay (EIA) and a conventional antibody conjugate assay. In 11 of these individuals, the antigen conjugate assay detected antibody to HIV-1 2 to 11 days (mean, 5.5 days) earlier than the antibody con...

متن کامل

Modification of rapid human immunodeficiency virus (HIV) antibody assay protocols for detecting recent HIV seroconversion.

Assay protocols of three rapid human immunodeficiency virus (HIV) assays, OraQuick-1/2, SeroStrip-1/2, and Determine-1/2, were modified to detect recent HIV seroconversion using a higher dilution of serum specimens. Optimal predilution of specimens resulted in negative test results during early periods of seroconversion (about 6 months), when antibody levels were low. A total of 269 seropositiv...

متن کامل

Comparison of two rapid human immunodeficiency virus (HIV) assays, Determine HIV-1/2 and OraQuick Advance Rapid HIV-1/2, for detection of recent HIV seroconversion.

Modified protocols of two rapid tests were compared with a less sensitive (LS) (detuned) enzyme immunoassay (EIA) for their abilities to distinguish recent human immunodeficiency virus (HIV) seroconversion from long-term infections. The results for samples from 100 HIV-positive patient that had previously been tested by the Vironostika LS EIA had a 97% concordance with the results of the Determ...

متن کامل

Evaluation of a New Anti-HIV1/2 ELISA–HIV 1/2 REC Diagnostic Kit Based on E. coli Derived Soluble Recombinant Proteins: Ex-perience of an International Study

Background/Objective: Development of a new enzyme-linked immunosorbent assay (ELISA) for screening human blood serum and plasma for antibodies to human immunodeficiency virus type 1 (HIV1) and type 2 (HIV2) as HIV1/2REC ELISA diagnostic kit based on E. coli derived soluble recombinant proteins. Methods: Polypeptides corresponding to HIV1 gp41 and HIV2 gp36 immunodominant regions and HIV1 gag we...

متن کامل

Multicenter evaluation of a new, automated enzyme-linked immunoassay for detection of human immunodeficiency virus-specific antibodies and antigen.

A collaborative multicenter study was conducted to evaluate the sensitivity, specificity, and precision of a three-step, fully automated, qualitative microparticle-based enzyme-linked immunoassay (AxSYM HIV Ag/Ab Combo; Abbott Laboratories), designed to simultaneously detect (i). antibodies against human immunodeficiency virus type 1 (HIV-1) and/or type 2 (HIV-2) and (ii). HIV p24 antigen. A si...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 42 6  شماره 

صفحات  -

تاریخ انتشار 2004