Complications of syndesmotic screw removal.

نویسندگان

  • Tim Schepers
  • Esther M M Van Lieshout
  • Mark R de Vries
  • Maarten Van der Elst
چکیده

BACKGROUND Currently, the metallic syndesmotic screw is the gold standard in the treatment of syndesmotic disruption. Whether or not this screw needs to be removed remains debatable. The aim of the current study was to determine the complications which occur following routine removal of the syndesmotic screw following operative treatment of unstable ankle fractures. METHODS This was a retrospective study with consecutive cases in a Level-2 Trauma center. All patients with routine removal of a syndesmotic screw, following the treatment of an unstable ankle fracture, between January 1, 2004 and November 30, 2010 were included. Complications recorded were: 1) minor or major wound infection following removal of the syndesmotic screw, 2) recurrent syndesmotic diastasis, and 3) unnecessary removal of a broken screw, not recognized during preoperative planning prior to surgery. RESULTS A total of 76 patients were included. A wound infection occurred in 9.2% (N = 7) of which 2.6% (N = 2) were deep infections requiring reoperation. Recurrent syndesmotic diastasis was found in 6.6% (N = 5) of patients, and in 6.6% (N = 5) screws were broken at the time of implant removal. In the group with recurrent diastasis the screws were removed significantly earlier compared with the group without recurrent diastasis (Mann-Whitney U-test; p = 0.011) and the group with screw breakage had their screws significantly longer in place compared with the group without breakage (p = 0.038). CONCLUSION A total of 22.4% complications occurred upon routine removal of the syndesmotic screw. Removal might therefore be considered only in selected cases with complaints, after a minimum of eight to twelve weeks and using antibiotic prophylaxis during removal.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Routine versus on demand removal of the syndesmotic screw; a protocol for an international randomised controlled trial (RODEO-trial)

BACKGROUND Syndesmotic injuries are common and their incidence is rising. In case of surgical fixation of the syndesmosis a metal syndesmotic screw is used most often. It is however unclear whether this screw needs to be removed routinely after the syndesmosis has healed. Traditionally the screw is removed after six to 12 weeks as it is thought to hamper ankle functional and to be a source of p...

متن کامل

A technique for removal of broken cannulated tricortical syndesmotic screws.

Breakage rates of tricortical syndesmotic screws after weight bearing range from 10% to 29%. Removal of the portion of the broken screw buried within the tibia often proves quite difficult. We report a new technique to remove a broken cannulated syndesmotic screw. This technique is simple, time saving, and less traumatic than previously reported methods of broken syndesmotic screw removal.

متن کامل

A systematic review of suture-button versus syndesmotic screw in the treatment of distal tibiofibular syndesmosis injury

BACKGROUND Now, using a suture-button device to treat distal tibiofibular syndesmotic injuries is overwhelming due to its advantages over screw fixation. Current systematic review was conducted to make a comparison between suture-button fixation and traditionally screw fixation in the treatment of syndesmotic injuries. The outcomes included functional outcomes, implant removal, implant failure,...

متن کامل

Technical aspects of the syndesmotic screw and their effect on functional outcome following acute distal tibiofibular syndesmosis injury.

INTRODUCTION Much of the currently available data on the technical aspects of syndesmotic screw placement are based upon biomechanical studies, using cadaveric legs with different testing protocols, and on surgeon preference. The primary aim of this study was to investigate the effect of the level of syndesmotic screw insertion on functional outcome. Further, the effects of number of cortices e...

متن کامل

ORTHOPAEDIC SURGERY To retain or remove the syndesmotic screw: a review of literature

Introduction Syndesmotic positioning screws are frequently placed in unstable ankle fractures. Many facets of adequate placement techniques have been the subject of various studies. Whether or not the syndesmosis screw should be removed prior to weight-bearing is still debated. In this study, the recent literature is reviewed concerning the need for removal of the syndesmotic screw. Materials a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Foot & ankle international

دوره 32 11  شماره 

صفحات  -

تاریخ انتشار 2011