Stent thrombosis after successful sirolimus-eluting stent implantation.

نویسندگان

  • Allen Jeremias
  • Brett Sylvia
  • Jonathan Bridges
  • Ajay J Kirtane
  • Brian Bigelow
  • Duane S Pinto
  • Kalon K L Ho
  • David J Cohen
  • Lawrence A Garcia
  • Donald E Cutlip
  • Joseph P Carrozza
چکیده

BACKGROUND Stent thrombosis (ST) is a rare but devastating complication of coronary stent implantation, occurring in 0.5% to 1.9% of patients with bare metal stents. The incidence of ST with drug-eluting stents is less well studied, particularly among patients outside of clinical trials. METHODS AND RESULTS The aim of this study was to evaluate the incidence and potential risk factors for ST in patients receiving sirolimus-eluting stents (SES) in the "real world" after commercial release in the United States in April 2003. All 652 patients who underwent SES implantation (776 lesions treated) at our institution between April and October 2003 were followed up prospectively after the procedure (median follow-up 100 days). During that period, 7 patients (1.1%, 95% CI 0.4% to 2.2%) developed ST within a range of 2 to 13 days, and 1 patient had an ST-elevation myocardial infarction on day 39 with evidence of thrombus within the SES at angiography. Patients with an ST had significantly smaller final nominal balloon diameters (2.75 versus 3.00 mm, P=0.04), and in 4 (57%) of the 7 patients with ST versus 1.7% of patients without ST (P<0.001), antiplatelet therapy had been discontinued after the procedure. Among the ST patients, 1 died and 5 had myocardial infarctions. CONCLUSIONS In this single-center experience, the incidence of ST after SES implantation was approximately 1%, which is within the expected range of bare metal stents. The discontinuation of antiplatelet therapy was strongly associated with the development of ST in this patient population.

منابع مشابه

Plasma brain natriuretic peptide-guided therapy not yet justified.

1. Iakovow I, Schmidt T, Bonizzoni E, et al. Incidence, predictors and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 2005;293:2126–30. 2. Kuchulakanti PK, Chu WW, Torguson R, et al. Correlates and long-term outcomes of angiographically proven stent thrombosis with sirolimus and paclitaxel-eluting stents. Circulation 2006;113; 1108 –13. 3. Alfonso F, Suarez A, ...

متن کامل

A Case of Stent Thrombosis Occurred at 5 Years after Sirolimus-Eluting Stent Implantation

Drug-eluting stents (DES) have reduced the rate of repeated revascularization of target lesions. For this reason, DES are considered to be superior to bare-metal stents in reducing the restenosis rate. However, some problems have been reported after implantation of DES. One of them, stent thrombosis, has arisen as a fatal complication. Dual antiplatelet therapy is recommended for at least 12 mo...

متن کامل

Stent thrombosis four and a half years after implantation of a sirolimus-eluting stent.

We report on a case of very late stent thrombosis, 51 months after implantation of a sirolimus-eluting stent and 15 months after clopidogrel discontinuation. This case underlines the possible need for long-term antiplatelet medication in patients receiving sirolimus-eluting stents.

متن کامل

Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study.

OBJECTIVES We sought to determine the predictors of stent thrombosis after sirolimus-eluting stent (SES) implantation. BACKGROUND A number of cases of stent thrombosis have been reported after commercial release of the SES in the "real world," such that the U.S. Food and Drug Administration issued a warning. METHODS Fifteen patients who developed stent thrombosis after successful SES implan...

متن کامل

Very Late Stent Thrombosis 42 Months after Implantation of Sirolimus-Eluting Stent and Discontinuation of Antiplatelet Therapy

Although safety profiles of sirolimus-eluting stents do not seem to differ in short-to-medium term from those of bare-metal stents, late stent thrombosis after deployment of drug-eluting stents has emerged as a potential safety concern in the era of high-pressure stent implantation. Here, we describe the case of a patient with acute myocardial infarction due to stent thrombosis of a sirolimus-e...

متن کامل

Late stent thrombosis in patients receiving ticlopidine and aspirin after sirolimus-eluting stent implantation.

BACKGROUND There is little information about the efficacy of ticlopidine plus aspirin after sirolimus-eluting stent (SES) implantation. METHODS AND RESULTS The incidence of stent thrombosis was evaluated in 1,029 patients receiving ticlopidine and aspirin after SES deployment. Clinical follow-up was obtained in 98.9% (mean follow-up 17.0+/-7.9 months). Early stent thrombosis was observed in 5...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • Zhonghua xin xue guan bing za zhi

دوره 35 11  شماره 

صفحات  -