The electron cyclotron resonance ion source with arc-shaped coils concept (invited).
نویسندگان
چکیده
The main limitation to further improve the performance of ECR ion sources is set by the magnet technology related to the multipole magnet field used for the closed minimum-B structure. The JYFL ion source group has sought different approaches to improve the strength of the minimum-B structure required for the production of highly charged ion beams. It was found out that such a configuration can be realized with arc shaped coils. The first prototype, electron cyclotron resonance ion source with arc-shaped coils (ARC-ECRIS), was constructed and tested at JYFL in 2006. It was confirmed that such an ion source can be used for the production of highly charged ion beams. Regardless of several cost-driven compromises such as extraction mirror ratio of 1.05-1.2, microwave frequency of 6.4 GHz, and beam line with limited capacity, Ar(4+) beam intensity of up to 2 μA was measured. Subsequent design study has shown that the ARC-ECRIS operating at the microwave frequency above 40 GHz could be constructed. This specific design would be based on NbTi-wires and it fulfills the experimental magnetic field scaling laws. In this article, the ARC-ECRIS concept and its potential applications will be described.
منابع مشابه
Cusped Mirror Magnetic Field for Electron Cyclotron Resonance Heavy Ion Source
Sufficient beams of Highly Charged Heavy Ions (HCHI) have been obtained in conventional electron cyclotron resonance ion sources (ECRIS) but at the cost of simplicity and economy. A cusped magnetic field (CMF) has more plasma-confining feature but a little current of HCHI’s was extracted from ECRIS using it. The CMF has been reconfigured adopting a simple, novel and cost-effective technique. It...
متن کاملConceptual Design of a Sputter-type Negative Ion Source Based on Electron Cyclotron Resonance Plasma Heating
A design for a negative ion source based on electron cyclotron resonance plasma heating and ionization by surface sputtering is presented. The plasma chamber of the source is an rf-cavity designed for TE111 eigenmode at 2.45 GHz. The desired mode is excited with a loop antenna. The ionization process takes place on a cesiated surface of a biased converter electrode (cathode). The ion beam is fu...
متن کاملElectron-beam extraction system for the Frankfurt 14 GHz electron cyclotron resonance ion source
A new concept to assist in the extraction of ion beams from an electron cyclotron resonance ion source ~ECRIS! by the injection of an electron beam from the extraction side into the ion-source plasma is proposed. In this article, the construction of a test setup is described and first results of experiments with this setup at the 14 GHz ECRIS of the Frankfurt ECRIS-~ve!RFQ facility are reported...
متن کاملEffect of accelerating electrode rotation on ion beam optics
Related Articles Wave frequency dependence of H− ion production and extraction in a transformer coupled plasma H− ion source at SNU Rev. Sci. Instrum. 83, 02A727 (2012) Physics research and technology developments of electron string ion sources Rev. Sci. Instrum. 83, 02A512 (2012) Pantechnik new superconducting ion source: PantechniK Indian Superconducting Ion Source Rev. Sci. Instrum. 83, 02A3...
متن کاملElectron acceleration and heating in collisionless magnetic reconnection
Related Articles Variation of the electron energy distribution with He dilution in an inductively coupled argon discharge Phys. Plasmas 19, 043505 (2012) Towards a better comprehension of plasma formation and heating in high performances electron cyclotron resonance ion sources (invited) Rev. Sci. Instrum. 83, 02A336 (2012) Commissioning of heating neutral beams for COMPASS-D tokamak Rev. Sci. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 83 2 شماره
صفحات -
تاریخ انتشار 2012