Direct cooling of the catheter tip increases safety for CMR-guided electrophysiological procedures

نویسندگان

  • Theresa Reiter
  • Daniel Gensler
  • Oliver Ritter
  • Ingo Weiss
  • Wolfgang Geistert
  • Ralf Kaufmann
  • Sabine Hoffmeister
  • Michael T Friedrich
  • Stefan Wintzheimer
  • Markus Düring
  • Peter Nordbeck
  • Peter M Jakob
  • Mark E Ladd
  • Harald H Quick
  • Wolfgang R Bauer
چکیده

BACKGROUND One of the safety concerns when performing electrophysiological (EP) procedures under magnetic resonance (MR) guidance is the risk of passive tissue heating due to the EP catheter being exposed to the radiofrequency (RF) field of the RF transmitting body coil. Ablation procedures that use catheters with irrigated tips are well established therapeutic options for the treatment of cardiac arrhythmias and when used in a modified mode might offer an additional system for suppressing passive catheter heating. METHODS A two-step approach was chosen. Firstly, tests on passive catheter heating were performed in a 1.5 T Avanto system (Siemens Healthcare Sector, Erlangen, Germany) using a ASTM Phantom in order to determine a possible maximum temperature rise. Secondly, a phantom was designed for simulation of the interface between blood and the vascular wall. The MR-RF induced temperature rise was simulated by catheter tip heating via a standard ablation generator. Power levels from 1 to 6 W were selected. Ablation duration was 120 s with no tip irrigation during the first 60 s and irrigation at rates from 2 ml/min to 35 ml/min for the remaining 60 s (Biotronik Qiona Pump, Berlin, Germany). The temperature was measured with fluoroscopic sensors (Luxtron, Santa Barbara, CA, USA) at a distance of 0 mm, 2 mm, 4 mm, and 6 mm from the catheter tip. RESULTS A maximum temperature rise of 22.4°C at the catheter tip was documented in the MR scanner. This temperature rise is equivalent to the heating effect of an ablator's power output of 6 W at a contact force of the weight of 90 g (0.883 N). The catheter tip irrigation was able to limit the temperature rise to less than 2°C for the majority of examined power levels, and for all examined power levels the residual temperature rise was less than 8°C. CONCLUSION Up to a maximum of 22.4°C, the temperature rise at the tissue surface can be entirely suppressed by using the catheter's own irrigation system. The irrigated tip system can be used to increase MR safety of EP catheters by suppressing the effects of unwanted passive catheter heating due to RF exposure from the MR scanner.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cryoablation with an 8-mm-Tip Catheter for Right-Sided Accessory Pathways in Children.

BACKGROUND Cryoablation is increasingly utilized in children because of its safety profile. Recently, larger catheter tips have been more widely used to improve long-term success rates. The aim of this study was to assess the safety and efficacy of 8-mm-tip catheters for cryoablation of right-sided accessory pathways (APs) in children. METHODS Electrophysiological procedures were performed us...

متن کامل

Popliteal catheter placement utilizing ultrasound needle guidance system

While ultrasound (US)-guided placement of peripheral nerve blocks is rapidly gaining popularity, expert practitioners agree that two of the most significant barriers to safety and efficacy are keeping the needle tip within the image and unintentional probe movement during the procedure.1 In addition, placing a nerve catheter past the needle tip under direct US observation requires two practitio...

متن کامل

MRI-conditional catheter sensor for contact force and temperature monitoring during cardiac electrophysiological procedures

Background MR-guided cardiac electrophysiological (EP) ablations has drawn increasing attention from both the MRI and EP communities, as high-contrast MR images provide images that couple anatomical information with lesion efficacy [1]. Catheter manipulation can be challenging for cardiac electrophysiologists as conventional electroanatomical maps, frequently include false space. Perforation of...

متن کامل

Interventional CMR

Introduction Interventional CMR has been undergoing rapid development because of the availability of MR compatible interventional catheters, and the increased performance of the MR systems themselves. Much of this development has benefited from the previous groundbreaking work in MRI guided surgical technologies ; however, intravascular techniques do not carry the requirement for an open access...

متن کامل

Comparison of Pregnancy Outcome between Ultrasound- Guided Tubal Recanalization and Office-Based Microhysteroscopic Ostial Dilatation in Patients with Proximal Blocked Tubes

Background The current research to the best of my knowledge is the first to compare the pregnancy outcome between ultrasound-guided tubal recanalization (UGTR) using a special fallopian tubal catheter, and office-based micrhysteroscopic ostial dilatation (MHOD) using the same tubal catherter in infertile women with previously diagnosed bilateral proximal tubal obstruction (PTO). MaterialsAndMet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012