Temporal limits of a rapidly swept Langmuir probe
نویسندگان
چکیده
The finite, electrostatically achievable, temporal resolution of plasma properties from a turbulent discharge is limited by an array of effects wherein the theory of Langmuir probes breaks down. Formulations for the particle transit time, sheath formation time, plasma-probe resonance, polarization current, sheath capacitance, stray capacitance, and mutual capacitance effects are all evaluated for time-resolved operation of a Langmuir probe. The resulting time scales serve to place a theoretical bound on the maximum rate of a rapidly swept Langmuir probe as analyzed with typical thin-sheath collisionless probe theory. For plasma typical to the plume of a Hall effect thruster xenon plasma, ne= 1–1000 10+15 m−3, and Te=1–20 eV , upper limits of 0.01–70 kHz are observed for a noncapacitive compensated Langmuir probe. With a high-speed dual Langmuir probe HDLP a regular probe plus a null compensation probe , the upper probing frequency limits are increased to 0.04–11 MHz limited by sheath capacitance in the far and near field, and polarization effects for closer internal measurements. For a typical tokamak edge plasma with HDLP , the thermally equilibrated hotter species typically Te Ti 10 to 20 eV and lighter ions together lend higher limiting rates of ion transit, sheath formation, and sheath capacitance effects in excess of 20 MHz , but the fully magnetized plasma complicates the collected probe current, limiting the allowable sweep rate to 1 MHz for a magnetic field of 2 T . Thus we find that the upper rate of Langmuir probe sweeping is in the low megahertz range for both electric thruster and fusion plasma device diagnostics. © 2010 American Institute of Physics. doi:10.1063/1.3449588
منابع مشابه
Influence of O2 and N2 Concentrations on the Characteristics of Plasma in DC Cylindrical Magnetron Discharge by Langmuir Probe
Using the Langmuir probe method, the reactive plasma parameters were studied in different ratios of oxygen and nitrogen concentrations in a DC cylindrical discharge device.The plasma parameters such as plasma potential, electron density and electron temperature wereextracted from the current-voltage characteristic’s curve of Langmuir probe to find the optimum conditions for deposit the oxy...
متن کاملEffects of rapidly decaying plasmas on Langmuir probe measurements
Sheath motion, displacement current, and probe edge effects on temporal Langmuir probe ~LP! ion saturation current measurements are investigated for a pulsed laser produced plasma during the period 100 ns→1000 ns after the turn on of the laser pulse. The plasma has a large volume ~hundreds of cm! and a high initial plasma density (ne.10 13 cm). The sheath motion and edge effects are found to be...
متن کاملPFC / JA - 94 - 24 A Dual - Cable Noise Reduction Method for Langmuir Probes
To obtain fast time response plasma properties, electron density and electron temperature, with a Langmuir probe the applied probe voltage has to be swept at high frequency. Due to the RC characteristics of coaxial cables, an induced noise of square waveform will appear when a sawtooth voltage is applied to the probe. Such a noise is very annoying and difficult to remove, particularly when the ...
متن کاملDouble Langmuir probe measurement of plasma parameters in a dc glow discharge
In this paper, plasma main characteristics such as electron mean temperature, electron number density, and oscillation frequency have been measured experimentally using the double Langmuir probe diagnostic system. In our experiment, the plasma was generated by applying the low pressure dc glow discharge in several common gases. The experimental results indicated the highest plasma density and o...
متن کاملHigh-speed dual Langmuir probe.
In an effort to temporally resolve the electron density, electron temperature, and plasma potential for turbulent plasma discharges, a unique high-speed dual Langmuir probe (HDLP) has been developed. A traditional single Langmuir probe of cylindrical geometry (exposed to the plasma) is swept simultaneously with a nearby capacitance and noise compensating null probe (fully insulated from the pla...
متن کامل