Minimally invasive transapical beating heart aortic valve implantation--proof of concept.

نویسندگان

  • Thomas Walther
  • Volkmar Falk
  • Michael A Borger
  • Todd Dewey
  • Gerhard Wimmer-Greinecker
  • Gerhard Schuler
  • Michael Mack
  • Friedrich W Mohr
چکیده

OBJECTIVE To evaluate the feasibility of minimally invasive transapical beating heart aortic valve implantation (TAP-AVI) for high-risk patients with aortic stenosis. METHODS TAP-AVI was performed via a small anterolateral minithoracotomy with or without femoral extracorporeal circulation (ECC) on the beating heart. A pericardial xenograft fixed within a stainless steel, balloon expandable stent (Cribier-Edwards, Edwards Lifesciences, Irvine, CA, USA) was used. Thirty consecutive patients (82 +/- 5.1 years, 21 (70%) female) were operated from 02/06 until 09/06 at one center using fluoroscopic and echocardiographic visualization. Average EuroSCORE predicted risk for mortality was 27 +/- 12%. RESULTS Valve positioning was successful in 29 patients and one required early conversion to full sternotomy. Implantation (8 mm x 23 mm and 22 mm x 26 mm valves) was performed on the beating heart during brief periods of rapid ventricular pacing. ECC was applied in 13 patients. Neither coronary artery obstruction nor migration of the prosthesis was observed and all valves displayed good hemodynamic function. Echocardiography revealed minor paravalvular leakage in 14 patients (trace in three, mild in nine and moderate in two). Three patients (10%) died, one on postoperative day (POD) three secondary to preoperative global myocardial failure and two on POD 18 and 86 due to abdominal complications. CONCLUSIONS Minimally invasive beating heart TAP-AVI is feasible. Initial results are encouraging in view of the high-risk profile of the patients. Long-term studies as well as randomized protocols are required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Valve-in-a-valve concept for transcatheter minimally invasive repeat xenograft implantation.

OBJECTIVES This study sought to evaluate the feasibility of minimally invasive transapical repeat valve-in-a-valve (VinV) implantation. BACKGROUND Reoperative heart valve replacement for degenerated xenografts is associated with an increased surgical risk. METHODS Conventional Carpentier Edwards porcine aortic (n = 5) and mitral (n = 2) valve prostheses were implanted in 7 pigs. Transapical...

متن کامل

Transapical minimally invasive aortic valve implantation; the initial 50 patients.

OBJECTIVE To evaluate the feasibility of minimally invasive transapical beating heart aortic valve implantation (TAP-AVI) for high-risk patients with aortic stenosis. METHODS TAP-AVI was performed via a small anterolateral minithoracotomy in 50 patients from February 2006 to March 2007. A balloon expandable transcatheter xenograft (Edwards SAPIEN THV, Edwards Lifesciences, Irvine, CA, USA) wa...

متن کامل

MR-Based Real Time Path Planning for Cardiac Operations with Transapical Access

Minimally invasive surgeries (MIS) have been perpetually evolving due to their potential high impact on improving patient management and overall cost effectiveness. Currently, MIS are further strengthened by the incorporation of magnetic resonance imaging (MRI) for amended visualization and high precision. Motivated by the fact that real-time MRI is emerging as a feasible modality especially fo...

متن کامل

Minimally Invasive Cardiac Surgery: Transapical Aortic Valve Replacement

Minimally invasive cardiac surgery is less traumatic and therefore leads to quicker recovery. With the assistance of engineering technologies on devices, imaging, and robotics, in conjunction with surgical technique, minimally invasive cardiac surgery will improve clinical outcomes and expand the cohort of patients that can be treated. We used transapical aortic valve implantation as an example...

متن کامل

Transapical minimally invasive aortic valve implantation: multicenter experience.

BACKGROUND To evaluate initial multicenter results with minimally invasive transapical aortic valve implantation (TAP-AVI) for high risk patients with aortic stenosis. METHODS AND RESULTS TAP-AVI was performed via a small anterolateral minithoracotomy with or without femoro-femoral extracorporeal circulation (ECC) on the beating heart. A pericardial xenograft fixed within a stainless steel, b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 31 1  شماره 

صفحات  -

تاریخ انتشار 2007