Analysis of Dose Distribution for the Gamma Cobalt Irradiation Therapy Unit in Normal and Emergency Conditions
نویسندگان
چکیده
The dose distribution inside the Gamma Cobalt irradiation therapy unit at Egyptian Atomic Energy Authority (EAEA) was determined both experimentally and theoretically. MCNP computer code, based on Monte Carlo method, was used to model the unit and calculate the dose distributions in both normal and emergency situation of the unit. The dose distribution inside the unit was also measured during the unit in operation. The maximum gamma dose distribution measured around the gamma device during operation (the source in position ON) using TLD and AD6-6150 was 2.21 and 2.010 mSv/h respectively, while the maximum gamma dose distribution calculated by MCNP computer code at the same point was 1.952 ± 0.026 mSv/h. The results indicate good agreement between the measurements and theoretical model of MCNP computer code. In case of emergency, and at 50 cm distance from the unit head the dose rate increases to 7000 μSv/h at the nearest point to the unit.
منابع مشابه
Comparison between Clinically Used Irregular Fields Shielded by Cerrobend and Standard Lead Blocks
Introduction: In radiation therapy centers across Iran, protection of normal tissues is usually accomplished by either Cerrobend or lead block shielding. In this study, the influence of these two shielding methods on central axis dose distribution of photon beam a Cobalt unit was investigated in clinical conditions. Materials and Methods: All measurements were performed for 60Co γ-ray beams an...
متن کاملEnhancing and verification of dose in external radiation therapy using Gd nanoparticles as a theranostic agent: A Monte Carlo simulation study
Introduction: Theranostics, in particular, the use of radionuclides with the capability of simultaneous imaging and treatment has opened new horizons in personalized treatment planning of targeted radiation therapy. In this approach, positive beta or gamma emitters are required for imaging and alpha, beta and Auger electrons for treatment purpose. On the other hand, studies hav...
متن کاملمعرفی روش جدید ارزیابی گاما وزن داده شده برای مقایسه توزیع دوز به دست آمده از الگوریتمهای محاسباتی دوز با نتایج تجربی در پرتودمانی
Introduction: One of the problems that exists in the quality control procedure of the treatment planning systems and the computer simulation of the radiotherapy or diagnostic radiology validation is comparing the dose distribution resulted from the dose calculation algorithms with the experimental results(as a reference). For this purpose, several methods have been proposed to compare these dos...
متن کاملThe Morphological Changes of Adult Mouse Testes after 60Co γ-Radiation
Background: Cytotoxic therapy can lead to prolonged azoospermia or even sterility. In the present study, we investigated the morphological changes of mouse testes after gamma-Radiation. Methods: After anaesthetizing of NMRI mice, testes and their surrounding tissues were irradiated using a cobalt therapy machine. Four experimental groups were irradiated with fractionated doses of: 1.5+8, 1.5+1...
متن کاملEvaluation of the Effects of Inhomogeneities on Dose Profiles Using Polymer Gel Dosimeter and Monte Carlo Simulation in Gamma Knife
Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...
متن کامل