Fresh Pericardial Valved Conduit for Reconstruction of Right Ventricular Outflow Tract in Tetralogy of Fallot with Pulmonary Stenosis or Pulmonary Atresia—Early Results
نویسندگان
چکیده
Objective: To study early results of hand made fresh (autologous/homologous) pericardial valved conduit in achieving right ventricle to pulmonary artery continuity. Method: Between November 2014 and September 2015, 19 cases, with diagnosis of Tetralogy of Fallot with Pulmonary stenosis (PS) or Pulmonary atresia (PA) underwent intracardiac repair and Right Ventricular Outflow Tract (RVOT) reconstruction with hand made fresh [autologous (n = 2)/ homologous (n = 17)] pericardial valved conduit. Mean age of the patients at time of surgery was 6.37 years (range 3 months to 18 years), mean weight was 18.52 kilograms (range 6 kg to 40 kg) and mean size of the conduit was 20.7 mm (range 16 mm to 24 mm). Results: All patients had a smooth post-operative course, with mean ICU (Intensive Care Unit) stay of 3.6 days (range 3 days to 6 days) and mean post-operative hospital stay 8.5 days (range 7 days to 16 days). Intra-operative and Post-operative echocardiography revealed moderate Pulmonary regurgitation (PR) in one patient, mild PR in 5 patients and no or trace PR in 13 patients. No patient has developed conduit stenosis or calcification till now. Conclusion: Autologous or homologous pericardial valved conduit provides good early results and is especially suitable for developing world because of zero cost. Long term usefulness of such option remains to be confirmed in terms of dilation, calcification and freedom from intervention.
منابع مشابه
Right ventricular outflow tract reconstruction with bicuspid valved polytetrafluoroethylene conduit.
BACKGROUND In general, all conduits available for right ventricular outflow tract (RVOT) reconstruction eventually become stenotic or insufficient. Owing to the lack of an ideal conduit and with the hope of reducing the incidence of reoperations, we have developed and utilized a bicuspid valved polytetrafluoroethylene (PTFE) conduit for the reconstruction of the RVOT. The purpose of this study ...
متن کاملThe contegra® valved heterograft conduit for right ventricular outflow tract reconstruction: a reliable solution.
INTRODUCTION The Contegra® bioprosthetic valved conduit, a glutaraldehyde-preserved valve-containing bovine jugular vein graft (Contegra, Medtronic Inc., Minneapolis MN, USA) introduced for clinical trials in 1998, is used for reconstruction of the right ventricular outflow tract (RVOT), mainly in children. This study evaluates our surgical experience with the Contegra® graft, emphasizing the a...
متن کاملReconstruction of right ventricular outflow with a valved homograft conduit.
Wheadey, D. J., Prusty, S., and Ross, D. N. (1974). Thorax, 29, 617-623. Reconstruction of right ventricular outflow with a valved homograft conduit. Since 1966 a conduit of homograft ascending aorta with its valve has been used for reconstruction of the right ventricular outflow. This technique has been applied to 123 operations for pulmonary autograft replacement of the aortic valve, 48 opera...
متن کاملContegra valved conduit in the paediatric population: an exciting prospect for right ventricle to pulmonary artery reconstruction; experience and outcomes at Aga Khan University.
OBJECTIVE The focus of this study is to share the experience and outcomes of Contegra graft implantation in the paediatric and adult population in Pakistan. METHODS Between May 2007 and July 2011, 16 patients, underwent implantation of a Contegra valved conduit. All operations were performed through a median sternotomy with cardiopulmonary bypass. Indications included: Pulmonary atresia with ...
متن کاملVentricular growth, measured by cardiac MRI, is not different in patients with tetralogy of fallot versus pulmonary atresia with intact ventricular septum or critical pulmonary stenosis after right ventricular outflow tract reconstruction
Background Cardiac MRI is used to measure right ventricular end diastolic volume indexed to body surface area (RVEDVi) and ejection fraction (EF) in the setting of pulmonary insufficiency (PI). There is data describing optimum RVEDVi, in tetralogy of fallot (TOF) patients, to provide a competent pulmonary valve and maintain long term RV function. Pulmonary atresia with intact ventricular septum...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017