Body surface infrared thermometry in patients with central venous cateter-related infections

نویسندگان

  • José Henrique Silvah
  • Cristiane Maria Mártires de Lima
  • Maria do Rosário Del Lama de Unamuno
  • Marco Antônio Alves Schetino
  • Luana Pereira Leite Schetino
  • Priscila Giácomo Fassini
  • Camila Fernanda Costa e Cunha Moraes Brandão
  • Anibal Basile
  • Selma Freire Carvalho da Cunha
  • Julio Sergio Marchini
  • José Henrique Silvah
  • Cristiane Maria Mártires de Lima
  • Maria do Rosário Del Lama de Unamuno
  • Marco Antônio Alves Schetino
  • Luana Pereira Leite Schetino
  • Priscila Giácomo Fassini
  • Camila Fernanda Costa e Cunha Moraes Brandão
  • Anibal Basile
  • Selma Freire Carvalho da Cunha
  • Julio Sergio Marchini
چکیده

OBJECTIVE To evaluate if body surface temperature close to the central venous catheter insertion area is different when patients develop catheter-related bloodstream infections. METHODS Observational cross-sectional study. Using a non-contact infrared thermometer, 3 consecutive measurements of body surface temperature were collected from 39 patients with central venous catheter on the following sites: nearby the catheter insertion area or totally implantable catheter reservoir, the equivalent contralateral region (without catheter), and forehead of the same subject. RESULTS A total of 323 observations were collected. Respectively, both in male and female patients, disregarding the occurrence of infection, the mean temperature on the catheter area minus that on the contralateral region (mean ± standard deviation: -0.3±0.6°C versus-0.2±0.5ºC; p=0.36), and the mean temperature on the catheter area minus that on the forehead (mean ± standard deviation: -0.2±0.5°C versus-0.1±0.5ºC; p=0.3) resulted in negative values. Moreover, in infected patients, higher values were obtained on the catheter area (95%CI: 36.6-37.5ºC versus 36.3-36.5ºC; p<0.01) and by temperature subtractions: catheter area minus contralateral region (95%CI: -0.17 - +0.33ºC versus -0.33 - -0.20ºC; p=0.02) and catheter area minus forehead (95%CI: -0.02 - +0.55ºC versus-0.22 - -0.10ºC; p<0.01). CONCLUSION Using a non-contact infrared thermometer, patients with catheter-related bloodstream infections had higher temperature values both around catheter insertion area and in the subtraction of the temperatures on the contralateral and forehead regions from those on the catheter area.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controle De Infecção Relacionada a Cateter Venoso Central Impregnado Com Antissépticos: Revisão Integrativa Control De Infección Relacionada Con Catéter Venoso Central Impregnado Con Antisépticos: Revisión Integradora

Infection control related to central venous catheter impregnated with antiseptics: an integrative review Ferreira MVF, Andrade D, Ferreira AM Rev Esc Enferm USP 2011; 45(4):993-7 www.ee.usp.br/reeusp/ Infection control related to central venous catheter impregnated with antiseptics: an integrative review* C r it iC a l r e v ie w CONTROLE DE INFECÇÃO RELACIONADA A CATETER VENOSO CENTRAL IMPREGN...

متن کامل

The Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections

Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...

متن کامل

Skin fold technique for central venous catheter fixation; Comparison with conventional method for postopration infections

Background: Central Venous Catheters (CVCs) are used not only as a tool to access to central venous system, but also for hemodynamic monitoring, parenteral nutrition, chemotherapy and hemodialysis. The use of CVCs is associated with some complications notably infections that are troublesome both to patient and physician. We conducted this study to examine catheter fixation with skin fold techni...

متن کامل

Antiseptic-impregnated central venous catheters: their evaluation in burn patients.

Central venous catheter-related infections are an important source of morbidity and mortality in burn patients. Antiseptic impregnated catheters have been recommended to prevent infections related to central venous lines in high-risk patients who require short-term catheters. This prospective, randomized, and controlled study compared the efficacy of standard and antiseptic devices in reducing ...

متن کامل

Evidence-based measures to prevent central line-associated bloodstream infections: a systematic review 1

OBJECTIVE to identify evidence-based care to prevent CLABSI among adult patients hospitalized in ICUs. METHOD systematic review conducted in the following databases: PubMed, Scopus, Cinahl, Web of Science, Lilacs, Bdenf and Cochrane Studies addressing care and maintenance of central venous catheters, published from January 2011 to July 2014 were searched. The 34 studies identified were organi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2015