Non-invasive quantification of brain glycogen absolute concentration.

نویسندگان

  • Florence D Morgenthaler
  • Ruud B van Heeswijk
  • Lijing Xin
  • Sabrina Laus
  • Hanne Frenkel
  • Hongxia Lei
  • Rolf Gruetter
چکیده

The only currently available method to measure brain glycogen in vivo is 13C NMR spectroscopy. Incorporation of 13C-labeled glucose (Glc) is necessary to allow glycogen measurement, but might be affected by turnover changes. Our aim was to measure glycogen absolute concentration in the rat brain by eliminating label turnover as variable. The approach is based on establishing an increased, constant 13C isotopic enrichment (IE). 13C-Glc infusion is then performed at the IE of brain glycogen. As glycogen IE cannot be assessed in vivo, we validated that it can be inferred from that of N-acetyl-aspartate IE in vivo: After [1-13C]-Glc ingestion, glycogen IE was 2.2 +/- 0.1 fold that of N-acetyl-aspartate (n = 11, R(2) = 0.77). After subsequent Glc infusion, glycogen IE equaled brain Glc IE (n = 6, paired t-test, p = 0.37), implying isotopic steady-state achievement and complete turnover of the glycogen molecule. Glycogen concentration measured in vivo by 13C NMR (mean +/- SD: 5.8 +/- 0.7 micromol/g) was in excellent agreement with that in vitro (6.4 +/- 0.6 micromol/g, n = 5). When insulin was administered, the stability of glycogen concentration was analogous to previous biochemical measurements implying that glycogen turnover is activated by insulin. We conclude that the entire glycogen molecule is turned over and that insulin activates glycogen turnover.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

O-45: Quantification of Cell-Free-Fetal-DNAfrom Maternal Plasma for the First Time in Pakistan:Implications for Non-Invasive PrenatalDiagnosis of Genetic Disorders

Background: Current prenatal diagnosis requires invasive testing which carries a 1-4% procedure-related-risk of miscarriage; hence, non-invasive techniques are desired. The recent demonstration of cell-free-fetal-DNA enriched from maternal plasma has opened new possibilities for non-invasive-prenatal-diagnosis of not only genetic-disorders such as β-thalassaemia and haemophilia but also chromos...

متن کامل

In vivo 13C NMR assessment of brain glycogen concentration and turnover in the awake rat.

Brain glycogen metabolism was recently observed in vivo and found to be very slow in the lightly alpha-chloralose anesthetized rat [J. Neurochem. 73 (1999) 1300]. Based on that slow turnover, the total glycogen content in the awake rat brain and its turnover time were assessed after administering 13C-labeled glucose for 48 h. Label incorporation into glycogen, glucose, amino acid, and N-acetyl-...

متن کامل

Biochemical quantification of total brain glycogen concentration in rats under different glycemic states.

All (13)C NMR studies of brain glycogen to date relied on observing the incorporation of (13)C label into glycogen, and thus interpretation was potentially affected by changes in (13)C label turnover rates. The goal of this study was to quantify total brain glycogen concentration under conditions of hypoglycemia or normoglycemia using biochemical methods. Rats were sacrificed using a focused mi...

متن کامل

Reproducibility and Absolute Quantification of Muscle Glycogen in Patients with Glycogen Storage Disease by 13C NMR Spectroscopy at 7 Tesla

Carbon-13 magnetic resonance spectroscopy (13C MRS) offers a noninvasive method to assess glycogen levels in skeletal muscle and to identify excess glycogen accumulation in patients with glycogen storage disease (GSD). Despite the clinical potential of the method, it is currently not widely used for diagnosis or for follow-up of treatment. While it is possible to perform acceptable 13C MRS at l...

متن کامل

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurochemistry

دوره 107 5  شماره 

صفحات  -

تاریخ انتشار 2008