Alveolar partial pressures of carbon dioxide and oxygen measured by a helium washout technique.
نویسنده
چکیده
A non-invasive technique was developed for measuring alveolar carbon dioxide and oxygen tension during tidal breathing. This was achieved by solving the Bohr equations for mean alveolar carbon dioxide and oxygen tensions (PACO2, PAO2) from known values of the dead-space:tidal volume ratio measured by helium washout, and from the mixed expired partial pressure of carbon dioxide and oxygen. The derived values of wPACO2 and wPAO2 were compared with PaCO2 obtained from arterial gas analysis and PAO2 calculated from the ideal air equation. Four normal subjects and 58 patients were studied. Calculated and measured PCO2 values agreed closely with a difference in mean values (wPACO2 - PaCO2) of 0.01 kPa; the SD of the differences was 0.7 kPa. The difference in mean values between wPAO2 and PAO2 was 0.02 kPa; the SD of the differences was 0.93 kPa. The method is simple and not time consuming, and requires no special cooperation from the patients. It can be applied in the laboratory or at the bedside to any subject breathing tidally. Physiological deadspace:tidal volume ratio, PAO2 and PACO2, static lung volumes, respiratory exchange ratio, carbon dioxide production, oxygen uptake, tidal volume, and total ventilation can be measured with acceptable accuracy and reproducibility in one test. An arterial blood sample is needed initially to provide an independent measure of PaCO2 and for measurement of the alveolar-arterial PO2 difference. Subsequently, PaCO2 can be estimated from wPACO2 sufficiently well for clinical purposes and PaO2 or SaO2 can be monitored by non-invasive methods.
منابع مشابه
Nitrogen washout/washin, helium dilution, and computed tomography in the assessment of end-expiratory lung volume
INTRODUCTION End expiratory lung volume (EELV) measurement in the clinical setting is routinely performed using the helium dilution technique. A ventilator that implements a simplified version of the nitrogen washout/washin technique is now available. We compared the EELV measured by spiral computed tomography (CT) taken as gold standard with the lung volume measured with the modified nitrogen ...
متن کاملModel-based administration of inhalation anaesthesia. 1. Developing a system model.
This paper is the first of a series of reports on a system model for the administration of inhalation anaesthesia. We present the development and basic testing of the model. It is a multiple-gas model; it covers fresh-gas flow rates from basal to more than total ventilation and includes an actual, not an idealized, circle-absorber breathing system featuring a standing bellows ventilator. Kineti...
متن کاملThe Equilibrium Solubility of Carbon Dioxide in the Mixed Aqueous Solutions of Triisopropanolamine and Monoethanolamine in the Range 30-70 C and Low Partial Pressures
The equilibrium solubility data of CO2 in the various aqueous blends of triisopropanolamine (TIPA) + monoethanolamine (MEA) with the total alkanolamine concentration of 2 mole / dm3 were measured at the temperatures of 30, 40, 50, 60 and 70 oC and CO2 partial pressures below 100 kPa. The experiments were done in an atmospheric gas absorption syste...
متن کاملGas exchange of algae. II. Effects of oxygen, helium, and argon on the photosynthesis of Chlorella pyrenoidosa.
Changes in the oxygen partial pressure of air over the range of 8 to 258 mm of Hg did not adversely affect the photosynthetic capacity of Chlorella pyrenoidosa. Gas exchange and growth measurements remained constant for 3-week periods and were similar to air controls (oxygen pressure of 160 mm of Hg). Oxygen partial pressures of 532 and 745 mm of Hg had an adverse effect on algal metabolism. Ca...
متن کاملNitrogen washout/washin, helium dilution and computed tomography in the assessment of end expiratory lung volume
Introduction End expiratory lung volume (EELV) measurement in the clinical setting is routinely performed using the helium dilution technique. A ventilator that implements a simplified version of the nitrogen washout/washin technique is now available. We compared the EELV measured by spiral computed tomography (CT) taken as gold standard with the lung volume measured with the modified nitrogen ...