Prompt gamma-ray analysis of chlorine in superpozz cement concrete
نویسندگان
چکیده
The chlorine concentration in Superpozz (SPZ) cement concrete was analyzed using a newly designed prompt gamma-ray neutron activation (PGNAA) setup utilizing a portable neutron generator. The setup, which mainly consists of a neutron source along with its moderator placed side by side with a shielded gamma-ray detector, allows determining chloride concentration in a concrete structure from one side. The setup has been tested through chlorine detection in chloride-contaminated Superpozz (SPZ) cement concrete specimens using 6.11 and 2.8673.10 MeV chlorine prompt gamma-rays. The optimum 0.03270.012 wt% value of Minimum Detectable Concentration (MDC) of chlorine in SPZ cement concrete measured in this study shows a successful application of a portable neutron generator in chloride analysis of concrete structure for corrosion studies. & 2012 Elsevier B.V. All rights reserved.
منابع مشابه
Chlorine signal attenuation in concrete.
The intensity of prompt gamma-ray was measured at various depths from chlorine-contaminated silica fume (SF) concrete slab concrete specimens using portable neutron generator-based prompt gamma-ray setup. The intensity of 6.11MeV chloride gamma-rays was measured from the chloride contaminated slab at distance of 15.25, 20.25, 25.25, 30.25 and 35.25cm from neutron target in a SF cement concrete ...
متن کاملCharacterization of Am-Be neutron source based PGNAA setup using aqueous solutions of Chlorine and Boron
Background: A 5 Ci 241Am-Be radio isotopic neutron source-based prompt gamma neutron activation analysis (PGNAA) setup was designed for estimation of minimum detectable concentration (MDC) of elements in aqueous solutions. Materials and Methods: Performance variables related to PGNAA setup (source to sample distance, sample to detector distance and volume of water) were optimized experimentally...
متن کاملPrompt gamma analysis of chlorine in concrete for corrosion study.
Measurement of chlorine in concrete is very important for studying of corrosion of reinforcing steel in concrete. Corrosion of reinforcing steel is primarily ascribed to the penetration of chloride ions to the steel surface. Preventive measures for avoiding concrete structure reinforcement corrosion requires monitoring the chloride ion concentration in concrete so that its concentration does no...
متن کامل60Co γ-ray attenuation coefficient of barite concrete
ABSTRACT Introduction: Recently uses of medium and high energy x-rays has been increased in Iran and radiotherapy centers along with a variety of accelerators have been installed in some provinces. In the other hand there is no sufficient skill in designing and making radiotherapy treatment rooms. This study was conducted to evaluate the efficacy of different m...
متن کاملExperimental Study on TGA, XRD and SEM Analysis of Concrete with Ultra-fine Slag (TECHNICAL NOTE)
The performances of cementitious materials as well as the efficiency of construction are adversely affected at high temperatures. Previous studies have already demonstrated that ultra-fine (alccofine) material accelerates the hydration of cement particles and subsequently improves the mechanical and durability properties of the concrete at normal temperature. Moreover, at higher temperatures th...
متن کامل