Air Transmission Comparison of the Affinity Fusion Oxygenator with an Integrated Arterial Filter to the Affinity NT Oxygenator with a Separate Arterial Filter.
نویسندگان
چکیده
Arterial filters used in the extracorporeal circuit (ECC) have been shown to minimize cerebral injury by capturing particulate matter and microbubbles. We clinically use the Affinity NT oxygenator with an Affinity arterial filter attached ("Affinity system"). The new Affinity Fusion oxygenator ("Fusion") incorporates integrated arterial filtering. Our aim was to determine if the Fusion oxygenator was as safe as the Affinity system in terms of relative microbubble transmission of introduced air. A recirculating in vitro circuit primed with blood was used to compare the Fusion with the Affinity system. Microbubbles were detected using a GAMPT BC100 Doppler in the oxygenator-arterial filter outflow line. Measurements were taken 1 minute before and 3 minutes after bolusing 30 mL air proximal to the venous reservoir while altering pump flow rates (3 L/min; 5 L/min). Both the Fusion and Affinity system transmitted microbubbles during air injection. Microbubble volume transmitted at 5 L/min pump flow was significantly greater than at 3 L/min in both systems. The Fusion tended to transmit fewer bubbles, less bubble volume, and smaller sized bubbles than the Affinity system. Under the parameters of this in vitro study, the Affinity Fusion oxygenator with an integrated arterial filter is as safe as the Affinity NT oxygenator with a separate arterial filter in terms of microbubble transmission. However, more research is needed to confirm this study's findings and generalizability to the clinical environment. As both oxygenator-arterial filter systems transmitted microbubbles during air introduction, it is important to develop strategies to minimize microbubble entry into the ECC.
منابع مشابه
Response to Letter "Working toward Best Practice: Microbubble Filtration and Patient Safety during Extracorporeal Circulation" by Daniel P. Herbst.
We thank Mr. Herbst for his comments and review of our article “Air transmission comparison of the Affinity Fusion oxygenator with an integrated arterial filter to the Affinity NT oxygenator with a separate arterial filter.” We designed this in vitro study to answer the question of whether the Fusion oxygenator with its integrated arterial filter was as safe as our clinically used Affinity NT o...
متن کاملWorking toward Best Practice: Microbubble Filtration and Patient Safety During Extracorporeal Circulation.
I have read with great interest the article from Potger et al. (1), and commend the authors for the contribution they make in this investigation. While congratulating them on their work, I also raise the following points to continue what I believe is much needed discussion on the very important topic of gas-bubble transmission during extracorporeal circulation (ECC). To build an appropriate con...
متن کاملPost-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study.
During a previously published study on gaseous microemboli (GMEs) and perfusionist interventions, it was noted that emboli could be detected after the arterial filter when blood/air challenges entered the membrane oxygenator's integral cardiotomy. The findings indicated that further study into the oxygenator's integral cardiotomy reservoir was warranted. This is the first know published report ...
متن کاملIn vitro validation of the Affinity NT oxygenator arterial outlet temperatures.
During cardiopulmonary bypass, the rates of cooling and rewarming and the maximum temperatures attained are implicated in patient morbidity. Thus, accurate oxygenator arterial outlet temperature measurements are needed. The purpose of this study was to determine the accuracy of the arterial outlet temperature probe on the "Affinity NT" membrane oxygenator in measuring perfusate temperatures. An...
متن کاملAn In-Vitro Study Comparing the GME Handling of Two Contemporary Oxygenators.
Gaseous microemboli (GME) are a potential complication of cardiopulmonary bypass (CPB). Though it is difficult to prove that GME is the only major cause of neurological deficits, it may increase the chance of post-operative cognitive dysfunction if not removed. The objectives of this research were to compare LivaNova-Sorin Inspire (Inspire) oxygenator with a Medtronic arterial filter to the Med...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 46 3 شماره
صفحات -
تاریخ انتشار 2014